Underestimation of Pupil Size by Critical Care and Neurosurgical Nurses

Author:

Kerr Robert G.1,Bacon Andrea M.1,Baker Laura L.1,Gehrke Janelle S.1,Hahn K. Danielle1,Lillegraven Cheryl L.1,Renner Catherine Hackett1,Spilman Sarah K.1

Affiliation:

1. Robert G. Kerr is a neurosurgeon at Hofstra North Shore–Long Island Jewish School of Medicine, Huntington, New York. Andrea M. Bacon is a critical care nurse, Laura L. Baker is a nurse practitioner, Janelle S. Gehrke is a clinical research coordinator, K. Danielle Hahn is a clinical research associate, Cheryl L. Lillegraven is a clinical nurse specialist, Catherine Hackett Renner is director of research, and Sarah K. Spilman is a research data analyst at UnityPoint Health, Des Moines, Iowa.

Abstract

Background Early detection of pupillary changes in patients with head injuries can alert the care team to increasing intracranial pressure. Previous research has shown inconsistencies in pupil measurement that are most likely due to the subjective nature of measuring pupils without the assistance of technology. Objectives To evaluate nurses’ abilities to assess pupil diameter accurately and detect unequal pupils. Methods In a 3-part study, the accuracy of critical care and neurosurgical nurses’ assessments of pupils was determined. The study included assessment of drawings of eyes with an iris and pupil, examination of photographs of human eyes, and bedside examination of patients with a head injury. Results Subjective assessments of pupil diameter and symmetry were not accurate. Across all phases of the study, pupil diameters were underestimated and the rate of error increased as pupil size increased. Nurses also failed to detect anisocoria and misidentified pupil reactivity. In addition, nearly all nurses relied on subjective estimation, even when tools were available. Conclusions Critical care and neurosurgical nurses underestimated pupil size, were unable to detect anisocoria, and incorrectly assessed pupil reactivity. Standardized use of pupil assessment tools such as a pupillometer is necessary to increase accuracy and consistency in pupil measurement and to potentially contribute to earlier detection of subtle changes in pupils. If pupillary changes are identified early, diagnostic and treatment intervention can be delivered in a more timely and effective manner.

Publisher

AACN Publishing

Subject

Critical Care Nursing,General Medicine

Cited by 47 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3