Total hip replacement after prior of the core decompression of the femoral head: efficacy and complications

Author:

Panin M. A.1ORCID,Zagorodnii N. V.2,Boiko A. V.3ORCID,Petrosyan A. S.3

Affiliation:

1. City Clinical Hospital No. 17; Patrice Lumumba Peoples' Friendship University of Russia

2. Patrice Lumumba Peoples' Friendship University of Russia

3. City Clinical Hospital No. 17

Abstract

Relevance. A history of core decompression using porous tantalum rods has a negative impact on the course of total hip arthroplasty surgery, the postoperative period and the frequency and nature of postoperative complications. Opinions are contradictory with regard to the effect of other techniques of necrosis decompression on total hip arthroplasty.Purpose of the study: evaluation of the effect of core decompression of the femoral head on the intraand postoperative parameters of total hip arthroplasty surgery.Object and methods. The study included 44 patients with osteonecrosis of the femoral head who underwent total hip arthroplasty. The first group consisted of 30 patients with osteonecrosis of the femoral head (ARCO grade II-IV) who had no previous hip surgery – primary total hip arthroplasty. The second group included 14 patients with osteonecrosis who had undergone the core decompression on the same joint (secondary total hip arthroplasty) 6–24 months earlier in stage II of the disease. The duration of surgery, blood loss volume, complications in the postoperative period, pain syndrome dynamics and hip joint function were assessed.Results. Comparative analysis showed the absence of significant technical intraoperative complications in total hip arthroplasty: duration of operations in group I – 85 ± 25 minutes, in group II – 80 ± 20 minutes, that is, almost identical; volume of intraoperative blood loss: 300 ± 100 ml in both groups. Survival rate of the hip replacement was 100 % in both groups. Superficial inflammation of the operating wound was diagnosed in 3.3 % of group I patients and in 7.1 % of group II patients (%). Dislocation of the hip replacement was observed in one patient in Group I (primary total hip arthroplasty). Twelve months after THA, osteolysis around the hip replacement element was detected by X-ray in 6.7 % of group I patients.Conclusion. Total hip arthroplasty in patients with a history of the core decompression of the femoral head is not accompanied by intraoperative technical difficulties and is a relatively safe surgical intervention. Prior core decompression is not an additional risk factor for intraand postoperative complications of total hip arthroplasty.

Publisher

Reaviz Medical University

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3