A pilot study of patch Holter electrocardiograph recordings in healthy cats

Author:

Ogawa Mizuki,Kaba Saran,Miyakawa Hirosumi,Hsu Huai,Miyagawa Yuichi,Takemura Naoyuki

Abstract

Background: A patch Holter electrocardiograph (P-Holter) is cordless, making it lightweight unlike the conventional Holter electrocardiograph (C-Holter). A P-Holter can also take continuous measurements. For up to 14 days without replacing the battery or SD card. Aim: The purpose of this study was to compare the performance of the P-Holter and the C-Holter in healthy cats. Additionally, we aimed to investigate whether multiday recordings with the P-Holter decrease sympathetic nerve activity or improve the accuracy of arrhythmia detection. Methods: Five healthy domestic short-haired cats were used for this study. Both a P-Holter and C-Holter were used on the first day, but only the P-Holter was used on days 2 to 6. The evaluated variables were the analyzable time of both Holter types, heart rate (HR), HR variability (HRV) and the number of arrhythmia occurrences. Results: For two out of the five cats, measurement of P-Holter was interrupted. Eventually, continuous recordings using the P-Holters were able to be collected from all individuals for 6 days. The 24 h analyzable time from the P-Holter and C-Holter was almost identical (p = 0.94). The 24 h mean HR did not differ across Holter types (p = 0.67). In addition, the timing of the occurrences of arrhythmias was almost identical to the P-Holter and C-Holter. Results of HRV suggested that sympathetic nerve activity was likely to decrease and vagal nerve activity was likely to increase after 4 to 5 days of measurement, compared to the second day of measurement (p < 0.05). When only the P-Holter was installed, the number of arrhythmia occurrences was similar on days 2 to 6. Conclusion: In this study, the P-Holter may be as useful as the C-Holter in cats with suspected intermittent arrhythmias, although these P-Holters were placed on cats without a clinical indication. However, cats may have individual differences in their adaptation to the device. P-Holter recordings taken for more than 4 to 5 days may allow the cat to acclimate to the device and reduce sympathetic nerve activity. The accuracy of arrhythmia detection across multiday P-Holter recordings requires further investigation using clinical cases.

Publisher

ScopeMed

Subject

General Veterinary

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3