Performance evaluation of the SMG HHV-6 Q Real-Time PCR Kit for quantitative detection and differentiation of human herpesvirus 6A and 6B

Author:

Kim Tae Yeul1ORCID,Park Min-Seung2ORCID,Yun Sun Ae3,Kang Minhee45ORCID,Kim Doo Ri6,Shin Areum6ORCID,Kim Hyun-Young1,Jang Mi-Ae1,Jang Ja-Hyun1,Kwon Min-Jung2,Huh Hee Jae17ORCID,Kim Yae-Jean67ORCID,Lee Nam Yong1ORCID

Affiliation:

1. Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea

2. Department of Laboratory Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, South Korea

3. Center for Clinical Medicine, Samsung Biomedical Research Institute, Samsung Medical Center, Seoul, South Korea

4. Biomedical Engineering Research Center, Smart Healthcare Research Institute, Samsung Medical Center, Seoul, South Korea

5. Department of Medical Device Management and Research, Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University, Seoul, South Korea

6. Department of Pediatrics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea

7. Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University, Seoul, South Korea

Abstract

ABSTRACT The aim of this study was to compare the performance of the newly developed SMG HHV-6 Q Real-Time PCR Kit (SMG assay) with the RealStar HHV-6 PCR Kit (RealStar assay). The analytical sensitivity and specificity, linearity, and precision of the SMG assay were evaluated. The clinical performance of the SMG assay was assessed and compared with that of the RealStar assay using 207 clinical specimens (HHV-6A positive, n = 51; HHV-6B positive, n = 64; HHV-6A/B negative, n = 92). The limit of detection of the SMG assay was 2.92 log 10 copies/mL for HHV-6A DNA and 2.88 log 10 copies/mL for HHV-6B DNA. The linear range was determined to be 3.40–9.00 log 10 copies/mL for both viruses. Intra- and inter-assay variability were below 5% at concentrations ranging from 4 to 9 log 10 copies/mL. No cross-reactivity was observed with the 25 microorganisms included in the specificity panel. The clinical sensitivity and specificity of the SMG and RealStar assays compared to in-house polymerase chain reaction and sequencing were as follows: SMG assay, 98.0% and 100% for HHV-6A DNA, respectively, and 96.9% and 100% for HHV-6B DNA, respectively; RealStar assay, 98.0% and 100% for HHV-6A DNA, respectively, and 90.6% and 100% for HHV-6B DNA, respectively. The correlation coefficients between viral loads measured by the two assays were 0.948 and 0.975, with mean differences of 0.62 and 0.32 log 10 copies/mL for HHV-6A and HHV-6B DNA, respectively. These results demonstrate that the SMG assay is a sensitive and reliable tool for the quantitative detection and differentiation of HHV-6A and HHV-6B DNA. IMPORTANCE Quantitative real-time PCR (qPCR) that can distinguish between HHV-6A and HHV-6B DNA is recommended for diagnosis of active infection. The SMG HHV-6 Q Real-Time PCR Kit (SMG assay) is a newly developed qPCR assay that can differentiate between HHV-6A and HHV-6B DNA; however, little is known about its performance. In this study, we assessed the performance of the SMG assay and compared it with that of a commercially available qPCR assay, the RealStar HHV-6 PCR Kit (RealStar assay). The SMG assay demonstrated excellent analytical sensitivity and specificity, precision, and linearity. Furthermore, the viral loads measured by the SMG assay were highly correlated with those measured by the RealStar assay. Our results suggest that the SMG assay is a useful diagnostic tool for quantitative detection and differentiation of HHV-6A and HHV-6B DNA.

Funder

Hwainmedics

Futre Medicine 2030 Project of the Samsung Medical Center

Publisher

American Society for Microbiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3