Development and evaluation of three automated media pooling and molecular diagnostic systems for the detection of SARS-CoV-2

Author:

Matsumura Yasufumi1ORCID,Noguchi Taro1,Shinohara Koh1,Yamamoto Masaki1,Nagao Miki1

Affiliation:

1. Department of Clinical Laboratory Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan

Abstract

ABSTRACT Pooled testing combined with molecular diagnostics for the detection of SARS-CoV-2 is a promising method that can increase testing capacities and save costs. However, pooled testing is also associated with the risks of decreased test sensitivity and specificity. To perform reliable pooled testing, we developed and validated three automated media pooling and molecular diagnostic systems. These pooling systems (geneLEAD-PS, Panther-PS, and Biomek-PS) comprised existing automated molecular detection platforms, corresponding automated media pooling devices, and laboratory information management systems. Analytical sensitivity analysis and mock sample evaluation were performed, and the obtained data were used to determine the sizes of the pool for the validation study. In the validation study, a total of 2,448, 3,228, and 6,420 upper respiratory samples were used for geneLEAD-PS, Panther-PS, and Biomek-PS, respectively, and the diagnostic performances were compared with the reference RT‒PCR assay. A pool size of 6 for geneLEAD-PS and a pool size of 4 for Panther-PS and Biomek-PS were selected for the validation studies. All three systems showed high positive percent agreement values of ≥90.5% and negative percent agreement values of ≥99.8% for any specimen type. Pooled testing resulted in a 65%–71% reduction in cost per sample. The testing capacities of geneLEAD-PS, Panther-PS, and Biomek-PS were 144 samples in 3 hours, 384 samples in 5.5 hours, and 376 samples in 4 hours, respectively. The developed pooling systems showed robust diagnostic performances and will increase the testing capacities of molecular diagnostic tests while saving costs and may contribute to infection control of COVID-19. IMPORTANCE During the COVID-19 pandemic, there have been surges in demand for accurate molecular diagnostic testing and laboratory supply shortages. Pooled testing combined with highly sensitive molecular testing, which entails mixing multiple samples as a single sample, is a promising approach to increase testing capacities while reducing the use of consumables. However, pooled testing is associated with risks that compromise diagnostic performance, such as false negatives due to dilution of positive samples or false positives due to cross-contamination. To perform reliable pooled testing, three different pooling systems (an automated pooling device, an automated molecular detection platform, and a laboratory information management system) were developed to accurately interpret pooled testing results. These three systems were validated using multiple clinical samples and showed high concordance with individual testing. The developed pooling systems will contribute to increasing reliable molecular testing capacities while using fewer consumables and saving costs.

Funder

Japan Agency for Medical Research and Development

Precision System Science

Beckman Coulter Foundation

Integra Biosciences

Nippon Control System

COVID-19 Private Fund

Publisher

American Society for Microbiology

Subject

Infectious Diseases,Cell Biology,Microbiology (medical),Genetics,General Immunology and Microbiology,Ecology,Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3