Sensitivity and Specificity of the ViroSeq Human Immunodeficiency Virus Type 1 (HIV-1) Genotyping System for Detection of HIV-1 Drug Resistance Mutations by Use of an ABI PRISM 3100 Genetic Analyzer

Author:

Eshleman Susan H.1,Crutcher Gillian2,Petrauskene Olga3,Kunstman Kevin4,Cunningham Shawn P.1,Trevino Christina5,Davis Cheryl6,Kennedy John7,Fairman Jeff8,Foley Brian9,Kop JoAnn2

Affiliation:

1. The Johns Hopkins Medical Institutions, Baltimore, Maryland

2. Celera Diagnostics, Alameda

3. Applied Biosystems, Foster City

4. Northwestern University, Chicago, Illinois

5. Stanford University, Palo Alto

6. PPGx, La Jolla

7. Los Alamos National Laboratory, Los Alamos, New Mexico;

8. Clingenix, Sunnyvale, California

9. Pompano Beach, Florida

Abstract

ABSTRACT The ViroSeq human immunodeficiency virus type 1 (HIV-1) genotyping system is an integrated system for identification of drug resistance mutations in HIV-1 protease and reverse transcriptase (RT). Reagents are included for sample preparation, reverse transcription, PCR amplification, and sequencing. Software is provided to assemble and edit sequence data and to generate a drug resistance report. We determined the sensitivity and specificity of the ViroSeq system for mutation detection using an ABI PRISM 3100 genetic analyzer with a set of clinical samples and recombinant viruses. Twenty clinical plasma samples (viral loads, 1,800 to 10,500 copies/ml) were characterized by cloning and sequencing individual viral variants. Twelve recombinant-virus samples (viral loads, approximately 2,000 to 5,000 copies/ml) were also prepared. Eleven recombinant-virus samples contained drug resistance mutations as 40% mixtures. One recombinant-virus sample contained an insertion at codon 69 in RT (100% mutant). Plasma and recombinant-virus samples were analyzed using the ViroSeq system. Each sample was analyzed on three consecutive days at each of three testing laboratories. The sensitivity of mutation detection was 99.65% for the clinical plasma samples and 99.7% for the recombinant-virus preparations. The specificity of mutation detection was 99.95% for the clinical samples and 100% for the recombinant-virus mixtures. The base calling accuracy of the 3100 instrument was 99.91%. Mutations in clinical plasma samples and recombinant-virus samples were detected with high sensitivity and specificity, including mutations present as mixtures. This report supports the use of the ViroSeq system for identification of drug resistance mutations in HIV-1 protease and RT genes.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3