Multicenter Evaluation of the Performance Characteristics of the Bayer VERSANT HCV RNA 3.0 Assay (bDNA)

Author:

Elbeik Tarek12,Surtihadi Johan3,Destree Mark4,Gorlin Jed4,Holodniy Mark5,Jortani Saeed A.6,Kuramoto Ken7,Ng Valerie12,Valdes Roland6,Valsamakis Alexandra8,Terrault Norah A.9

Affiliation:

1. Department of Laboratory Medicine

2. Clinical Laboratories at San Francisco General Hospital, San Francisco

3. Department of Biostatistics, Diagnostics Division, Bayer Healthcare LLC, Berkeley

4. Memorial Blood Center of Minneapolis, Minneapolis, Minnesota

5. AIDS Research Center, Veterans Administration Palo Alto Health Care System and Division of Infectious Diseases and Geographic Medicine, Stanford University, Palo Alto

6. Department of Pathology and Laboratory Medicine, University of Louisville School of Medicine, Louisville, Kentucky

7. BloodSource, Center for Blood Research, Sacramento, California

8. Department of Pathology, Johns Hopkins Medical Institutions, Baltimore, Maryland

9. Department of Medicine, Division of Gastroenterology, University of California, San Francisco

Abstract

ABSTRACT In this multicenter evaluation, the VERSANT HCV RNA 3.0 Assay (bDNA) (Bayer Diagnostics, Tarrytown, N.Y.) was shown to have excellent reproducibility, linearity, and analytical sensitivity across specimen collection matrices (serum, EDTA, ACD-A), and hepatitis C virus (HCV) genotypes 1 to 6. The VERSANT HCV bDNA Assay has a reportable range of 615 to 7,690,000 (7.69 × 10 6 ) IU/ml. The total coefficient of variation (CV) ranged from 32.4% at 615 IU/ml to 17% at 6.8 × 10 6 IU/ml. The assay was linear across the reportable range. Analytical specificity of 98.8% was determined by testing 999 specimens from volunteer blood donors. Evaluation of HCV genotypes using RNA transcripts of representative clones of 1a, 1b, 2a, 2b, 2c, 3a, 4a, 5a, and 6a and patient specimens showed that the largest difference between genotype 1, upon which the assay is standardized, and non-1 genotypes was within 1.5-fold. Testing of potentially interfering endogenous substances and exogenous substances and conditions found no interference in HCV-positive or HCV-negative specimens except for unconjugated bilirubin at concentrations of ≥20 mg/dl and protein at concentrations of ≥9 g/dl. Biological variability was estimated from 29 clinically stable individuals not on HCV therapy who were tested weekly over an 8-week period. The combined estimate of total (biologic plus assay) variability was 0.15 log 10 standard deviation (CV, 36.1%), a fold change of 2.6. Thus, the observed fold change between any two consecutive HCV RNA measures is expected to be less than 2.6-fold (equivalent to 0.41 log 10 IU/ml) 95% of the time in clinically stable individuals.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3