Affiliation:
1. Department of Immunology, Ernst-Rodenwaldt-Institute, Koblenz, Federal Republic of Germany.
Abstract
Tetanus antitoxin in human sera was detected with solid-phase immunoassays in microtitration modules coated with tetanus toxoid by using Eu(3+)-labeled anti-human monoclonal antibodies on the basis of an exactly calibrated antibody standard. The use of a time-resolved fluorescence immunoassay (TR-FIA) significantly improved the quantitative detection of tetanus antitoxin over that of the enzyme-linked immunosorbent assay (ELISA) technique because of its high sensitivity and its wide measurement range, detecting antibody levels between 0.001 and 12.5 IU/ml with a single serum dilution of 1:100. For the same purpose, two different serum dilutions (1:100 and 1:1,000) were needed in the ELISA technique. TR-FIA is reproducible and can be performed in 3.5 h. A study of 2,630 serum samples was undertaken to examine the age-dependent distribution of titer levels, indicating the decline of sufficient protection in patients older than 60 years. The wide measurement range of TR-FIA enabled fast examination of large numbers of serum samples without the need for repetition, with further sample dilution, as was often necessary in the ELISA procedure.
Publisher
American Society for Microbiology