Investigation of geometry-dependent sensing characteristics of microfluidic for single-cell 3D localization

Author:

Wang Tan1,Fang Qiang1,Huang Liang1ORCID

Affiliation:

1. Anhui Province Key Laboratory of Measuring Theory and Precision Instrument and School of Instrument Science and Opto-Electronics Engineering, Hefei University of Technology , Hefei 230009, China

Abstract

Flow cytometry-based measurement techniques have been widely used for single-cell characterizations, such as impedance, size, and dielectric properties. However, in the measurement process, the reliability of the output measurement signal directly affects the ability of the microsystem to judge the characteristics of single cells. Here, we designed a multiple nonparallel electrode structure for single-cell 3D localization. The performance of the structures was studied by analyzing the changes in electric field strength and the output differential current. The effects of microchannel height, sensing electrode distance, electrode inclination angle, and electrode width on output signals are investigated by analyzing the current change and electric field strength of single cells passing from the center of the microchannel. The numerical simulation results indicate that, when the microchannel height is 20 µm, the distance of the sensing electrodes is 100 µm, the inclination angle is 30°, the electrode width is 20 µm, and the optimal signal quality can be obtained. Reducing the height of the flow channel and shortening the sensing electrode spacing can significantly improve the signal amplitude. When the channel height is 20 µm, the signal intensity increases by 80% than that of 30 µm. The signal intensity of induced current with the sensing electrode spacing of 100 µm is 42% higher than that with the spacing of 120 µm. We analyzed the presence of multiple independent cells and adherent cells in the detection area and demonstrated through simulation that the signal changes caused by multi-cells can be superimposed by multiple single-cell signals. The induced current signal intensity of the same volume of cells with an ellipticity of 1 is 49% lower than that of cells with an ellipticity of 4. Based on the numerical investigation, we expect that the optimal geometry structure design will aid in the development of better performance signal cell impedance cytometry microsystems.

Funder

National Natural Science Foundation of China

Natural Science Foundation of Anhui Province

Fundamental Research Funds for the Central Universities

Publisher

AIP Publishing

Subject

Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3