Abstract
An experimental investigation is conducted to examine the impact of nitrogen fraction on vented explosions of hydrogen–air–nitrogen mixtures in a 1-m-long cylindrical duct at 1 bar and 281 K. The study employs high-speed shadowgraph imaging, a pressure testing system, and infrared thermal imaging to record the venting process. The results showed that as the nitrogen fraction increases, the rupture time of the vent cover gradually increases. However, the internal peak overpressure exhibits an opposite trend, with P2 (caused by the ignition of unburned gas outside the tube by the escaping flame) near the vent consistently dominating. The frequency of Helmholtz oscillations initially decreases and then increases with increasing nitrogen fraction. Higher nitrogen fractions are associated with a greater likelihood of lower external peak overpressure but a decreasing trend in maximum external impulse. The maximum temperature shows an initial decrease followed by an increase with the addition of nitrogen fraction. This trend is also observed for flame length, flame width, high-temperature duration (>500 °C), and heat energy. Furthermore, the study determined safety zones that are free from thermal radiation damage.
Funder
Natural Science Foundation of Jiangsu Province
Postdoctoral Research Foundation of China
National Postdoctoral Program for Innovative Talents
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献