LeViness A.1ORCID,Lazerson S. A.2ORCID,Jansen van Vuuren A.3ORCID,Rueda-Rueda J.4ORCID,Ayllon-Guerola J.4ORCID,Bozhenkov S.2ORCID,Corl D.1ORCID,Ellis R.1ORCID,Galdon-Quiroga J.4ORCID,Garcia-Dominguez J.1ORCID,Garcia-Munoz M.4ORCID,Hidalgo-Salaverri J.4ORCID,Ogawa K.5ORCID,Pablant N.1ORCID,Segado-Fernandez J.4ORCID,

Affiliation:

1. Princeton Plasma Physics Laboratory 1 , Princeton, New Jersey 08540, USA

2. Max Planck Institute for Plasma Physics 2 , Greifswald 17491, Germany

3. Swiss Federal Institute of Technology Lausanne 3 , Lausanne 1015, Switzerland

4. University of Seville 4 , Seville 41004, Spain

5. National Institute for Fusion Science 5 , Toki 509-5202, Japan

Abstract

A quantitative theoretical framework has been created to model neutral beam injection and fast ion losses in the Wendelstein 7-X (W7-X) stellarator, including a novel method to develop synthetic diagnostics for fast ion loss detectors (FILDs) of many types, such as scintillating and Faraday Cup FILDs. This is the first time that this has been done in stellarator geometry with this level of fidelity, providing a way for fast ion losses to be predicted more precisely in future stellarator experiments and in W7-X. Simulations of the signal seen by a Faraday Cup FILD have been completed for multiple W7-X plasmas and show close agreement with the measured signals. This method is now applied to an actively water-cooled, scintillator-based FILD, which is currently in development to measure the fast ion loss distribution in W7-X in greater detail. The design makes use of a double slit to measure energy-and-pitch-angle-resolved losses of both co-going and counter-going fast ions. The diagnostic, which can be inserted to different radial positions, has been designed to withstand steady-state heat fluxes of up to 120 kW/m2 along with additional transient heat loads of 100 kW/m2 lasting for up to 20 s at a time. Simulations of W7-X standard magnetic configuration show up to 8 × 1013 (s−1 cm−2) ion fluxes onto the sensor from each neutral beam source and no signal from the counter-going slit. These simulations will help inform experimental proposals for future W7-X campaigns after installation of this diagnostic.

Funder

U.S. Department of Energy

EUROfusion

Publisher

AIP Publishing

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3