Affiliation:
1. TRIUMF, Vancouver, British Columbia V6T 2A3, Canada
Abstract
A 15 mA dc H− multicusp source has been developed for injection into a TR30 cyclotron. This source is also used with a 900 kV tandem accelerator to obtain 10 mA protons at 1.8 MeV. The program is an extension of the 5–7 mA dc H− cusp source developed at TRIUMF during 1989–1990. Major efforts include the search for the optimal filament materials, shape, and location; comparison of cusp line confinement and magnetic filtering of electrons at the extraction region; optimization of extraction lense configuration; and upgrading of vacuum and power systems capability. The source is noncesiated and the maximum arc power available is only 5 kW. After the H− beams pass through an electron suppression grid and a 20 mm collimator, we obtained 15 mA with 0.66 π mm mrad 4 rms normalized emittance. At this output the e/H ratio was about 4. The best normalized emittance occurs around 5–7 mA, having a value of 0.37 π mm mrad. Further development in the near future is planned using cesium and multiple apertures in the hope of increasing dc H− currents to 30 mA while holding the normalized emittance below 0.75 π mm mrad.
Cited by
63 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献