Modality for estimating NMR relaxation time using perturbed angular correlation in double-photon emission nuclides

Author:

Matsumoto Wataru1ORCID,Feng Boyu2,Tamai Yoshiki1,Ueki Taisei1,Kamada Kei3,Uenomachi Mizuki4,Tomita Hideki5ORCID,Fushimi Motofumi1ORCID,Shimazoe Kenji12,Takahashi Hiroyuki12,Sekino Masaki1ORCID

Affiliation:

1. Department of Bioengineering, The University of Tokyo 1 , Bunkyo, Tokyo 113-8656, Japan

2. Department of Nuclear Engineering and Management, The University of Tokyo 2 , Bunkyo, Tokyo 113-8656, Japan

3. Department of Energy Engineering, Nagoya University 3 , Nagoya, Aichi 464-8603, Japan

4. Division of Physics and Astronomy, Kyoto University 4 , Sakyo, Kyoto 606-8502, Japan

5. New Industry Creation Hatchery Center (NICHe), Tohoku University 5 , Sendai, Miyagi 980-8579, Japan

Abstract

T2 relaxation time in magnetic resonance imaging (MRI), which is determined by magnetic dipole interactions, has been employed as a parameter for tumor detection. However, owing to the lack of MRI detection sensitivity, nuclear medicine imaging is currently the basic option for tracking low concentrations of chemical probes. Previous studies utilizing cascade radionuclides have focused on the relaxation due to electric quadrupole interactions. However, magnetic dipole interactions, which are crucial in MRI, remains to be elucidated. In this study, we determined the magnetic relaxation rate by using 111In, a cascade radionuclide used in clinical single-photon emission computed tomography (SPECT) scans. As the angle between the gamma rays from the nuclei is affected by the electrical and magnetic interactions acting on the nuclei, we measured the angular correlation ratio by using eight gadolinium gallium garnet (GAGG) multi-pixel photon counter (MPPC) 8 × 8 array detectors and extracted the magnetic relaxation rate. Consequently, we obtained a rate that increased with the Fe concentration, similar to the T2 relaxation rate, although it was influenced by the inhomogeneity of the external magnetic field. This study utilized low concentrations of the liquid-state radionuclide, which is commonly used in clinical nuclear medicine imaging scans and is expected to provide much higher sensitivity and more selective detection of tumors than conventional MRI.

Funder

Japan Society for the Promotion of Science

Publisher

AIP Publishing

Subject

General Physics and Astronomy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3