VISUAL ACUITY AND ILLUMINATION IN DIFFERENT SPECTRAL REGIONS

Author:

Shlaer Simon1,Smith Emil L.1,Chase Aurin M.1

Affiliation:

1. From the Laboratory of Biophysics, Columbia University, New York

Abstract

The relation between visual acuity and illumination was measured in red and blue light, using a broken circle or C and a grating as test objects. The red light data fall on single continuous curves representing pure cone vision. The blue light data fall on two distinct curves with a transition at about 0.03 photons. Values below this intensity represent pure rod vision. Those immediately above represent the cooperative activity of rods and cones, and yield higher visual acuities than either. Pure cone vision in this intensity region is given by central fixation (C test object). All the rest of the values above this transition region represent pure cone vision. In blue light the rod data with the C lie about 1.5 log units lower on the intensity axis (cone scale) than they do in white light, while with the grating they lie about 1.0 log unit lower than in white light. Both the pure rod and cone data with the C test object are precisely described by one form of the stationary state equation. With the grating test object and a non-limiting pupil, the pure rod and cone data are described by another form of the same equation in which the curve is half as steep. The introduction of a small pupil, which limits maximum visual acuity, makes the relation between visual acuity and illumination appear steeper. Determinations of maximum visual acuities under a variety of conditions show that for the grating the pupil has to be larger, the longer the wavelength of the light, in order for the pupil not to be the limiting factor. Similar measurements with the C show that when intensity discrimination at the retina is experimentally made the limiting factor in resolution, visual acuity is improved by conditions designed to increase image contrast. However, intensity discrimination cannot be the limiting factor for the ordinary test object resolution because the conditions designed to improve image contrast do not improve maximum visual acuity, while those which reduce image contrast do not produce proportional reductions of visual acuity.

Publisher

Rockefeller University Press

Subject

Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3