Experience with percutaneous right ventricular support in the early post-left ventricular assist device implantation period (clinical case report and literature reviews)

Author:

Poptsov V. N.1,Spirina E. A.1,Ryabtsev D. V.1,Solodovnikova A. K.1,Epremian A. S.1

Affiliation:

1. Shumakov National Medical Research Center of Transplantology and Artificial Organs

Abstract

Implantable left ventricular assist device (LVAD) is a state-of-the-art treatment for adults and children with end-stage heart failure. The early and late period after LVAD implantation can be severely complicated. Right ventricular failure (RVF) still remains a common complication after LVAD implantation. RVF is the cause of reduced post-implant survival. We suggest that an additional temporary or permanent right ventricular assist device (RVAD) is an effective treatment for LVAD-associated RVF. In this clinical case report, we describe the medical history of a pediatric patient (14 years old) with severe heart failure (PediMACS Level 1) against a background of dilated cardiomyopathy. The patient required peripheral venoarterial extracorporeal membrane oxygenation (VA-ECMO) prior to urgent LVAD (HM3) implantation. In the early post-LVAD implantation (1 POD) period, the patient presented with hemodynamic and echocardiographic events of acute RVF that was resistant to drug therapy (inotropic/vasopressor support, iNO) and required mechanical circulatory support (MCS) with a preoperatively implanted VA-ECMO. In the LVAD-associated RVF scenario, VA-ECMO as a means of total cardiac bypass is a non-physiological MCS method and, therefore, undesirable. In this clinical situation, our solution was to use a paracorporeal centrifugal blood pump for temporary right heart support. A RVAD was assembled using percutaneous cannulation in two sites and a modification of the pre-existing VA-ECMO circuit. For RVAD, we used an ECMO cannula previously installed through the femoral vein (26 F) and added a reverse venous cannula (22 F) through the right internal jugular vein into the pulmonary trunk. To facilitate the passage of the return cannula into the pulmonary artery, we used a contralateral sheath (6 F, 40 cm) and an Amplatz Super Stiff guidewire under radiological control. The oxygenator was removed from the circuit on day 2 of RVAD. Central hemodynamics (reduction in right atrial pressure (RAP) to 10 mm Hg, increase in pulmonary capillary wedge pressure (PCWP) to 14 mm Hg), as well as right ventricular (RV) and left ventricular (LV) volume characteristics all improved. These observations allowed us to optimize the performance of the implantable LVAD (increase in flow rate to 4.2 l/min or 2.1 l/min/m2). The duration of paracorporeal RVAD after LVAD implantation was 7 days with an average flow rate of 2.3 ± 0.2 l/min. Postoperative treatment in the intensive care unit (ICU) lasted for 15 days. The patient was discharged from the hospital on postoperative day 34.

Publisher

V.I. Shimakov Federal Research Center of Transplantology and Artificial Organs

Subject

Transplantation,Immunology and Allergy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3