Effect of second warm ischemia elimination on kidney graft function: an experiment and clinical study

Author:

Shabunin A. V.1,Drozdov P. A.2,Makeev D. A.2,Nesterenko I. V.2,Zhuravel O. S.1,Astapovich S. A.2,Lidjieva E. A.3

Affiliation:

1. Botkin Moscow City Clinical Hospital; Russian Medical Academy of Continuous Professional Education

2. Botkin Moscow City Clinical Hospital

3. Sechenov University

Abstract

Objective: to evaluate the effectiveness of a new device for second warm ischemia (SWI) elimination in kidney transplantation (KT).Materials and methods. The study included clinical and experimental stages. The clinical stage included 63 patients out of 219 who underwent KT at Botkin Moscow City Clinical Hospital between July 2018 and August 2022. The inclusion criteria were kidneys from donation after brain death (DBD) donors with expanded criteria or kidneys from donation after circulatory death (DCD) donors, and an SWI time greater than 45 minutes. The first group consisted of 24 recipients operated on using the new SWI elimination device. The second retrospective control group consisted of 39 patients where sterile ice bags were used at the implantation stage. The groups had no statistically significant differences in the main recipient and donor characteristics, as well as in perioperative parameters. Also, from November 2021 to April 2022, 23 kidney autotransplantation experiments in female Landrace pigs were performed. The animals were cared for in accordance with the European Convention for the Protection of Vertebrate Animals used for Experimental and other Scientific Purposes (Strasbourg, 18 March 1986). Efficiency of different SWI elimination techniques was compared on two experimental models: standard donor (group 1, n = 12) and asystolic donor (group 2, n = 11).Results. In the clinical trial group, mean graft temperature (tm) before reperfusion was statistically significantly lower in group 1 using the special SWI elimination device: 6.4 ± 1.7 °C (95% CI 3.2–8.5) versus 22.1 ± 2.3 °C (18.1–24.6), р < 0.001. The risk of delayed graft function (DGF) was 3.86 times higher (95% CI 1.11–13.43) with the standard SWI elimination technique. In the experimental group, in the subgroups using the new device (n = 12), graft tm before reperfusion was 5.1 ± 0.4 °C (95% CI 4.5–5.8), whereas in the ice bag subgroups (n = 11), tm was 29.3 ± 1.3 °C (95% CI 27.7–30.8), which was significantly higher (p < 0.001). The overall 1-week survival of the experimental animals was significantly higher in the SWI elimination device subgroup (logrank p = 0.036).Conclusion. The developed device is effective in eliminating SWI of renal graft.

Publisher

V.I. Shimakov Federal Research Center of Transplantology and Artificial Organs

Subject

Transplantation,Immunology and Allergy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3