Association of cardiac preservation solution with short-term outcomes after heart transplantation

Author:

Suarez-Pierre Alejandro,Iguidbashian John,Kirsch Michael J.,Cain Michael T.,Aftab Muhammad,Reece T. Brett,Fullerton David A.,Rove Jessica Y.,Cleveland Joseph C.,Hoffman Jordan R.H.

Abstract

Aims There is wide variability in the practice of cardiac preservation for heart transplantation. Prior reports suggest that the type of solution may be linked with a reduced incidence of posttransplantation complications. Methods Adult (≥18 years old) heart recipients who underwent transplantation between 2015 and 2021 in the United States were examined. Recipients were stratified by solution utilized for their grafts at the time of recovery: University of Wisconsin, histidine–tryptophan–ketoglutarate (HTK), or Celsior solution. The primary endpoint was a composite of 30-day mortality, primary graft dysfunction, or re-transplantation. Risk adjustment was performed for the recipient, donor, and procedural characteristics using regression modeling. Results Among 16 884 recipients, the group distribution was University of Wisconsin solution 53%, HTK 22%, Celsior solution 15%, and other 10%. The observed incidence of the composite endpoint (University of Wisconsin solution = 3.6%, HTK = 4.0%, Celsior solution = 3.7%, P = 0.301) and 1-year survival (University of Wisconsin solution = 91.7%, HTK = 91.3%, Celsior solution = 91.7%, log-rank P = 0.777) were similar between groups. After adjustment, HTK was associated with a higher risk of the composite endpoint [odds ratio (OR) 1.249, 95% confidence interval (CI) 1.019–1.525, P = 0.030] in reference to University of Wisconsin solution. This association was substantially increased among recipients with ischemic periods of greater than 4 h (OR 1.817, 95% CI 1.188–2.730, P = 0.005). The risks were similar between University of Wisconsin solution and Celsior solution (P = 0.454). Conclusion The use of the histidine–tryptophan–ketoglutarate solution during cold static storage for cardiac preservation is associated with increased rates of early mortality or primary graft dysfunction. Clinician discretion should guide its use, especially when prolonged ischemic times (>4 h) are anticipated.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3