Accuracy of Nine Formulas to Calculate the Powers of an Extended Depth-of-Focus IOL Using Two SS-OCT Biometers

Author:

Jeon Sohee,Taroni Leonardo,Lupardi Enrico,Hoffer Kenneth J.,Fontana Luigi,Schiano-Lomoriello Domenico,Kwon Hyunggoo,Savini Giacomo

Abstract

Purpose: To evaluate the accuracy of nine formulas to calculate the power of a new extended depth-of-focus intraocular lens (EDOF IOL), the AcrySof IQ Vivity (Alcon Laboratories, Inc), using measurements from two optical biometers, the IOLMaster 700 (Carl Zeiss Meditec AG) and Anterion (Heidelberg Engineering GmbH). Methods: After constant optimization, the accuracy of these formulas was analyzed in 101 eyes: Barrett Universal II, EVO 2.0, Haigis, Hoffer Q, Holladay 1, Kane, Olsen, RBF 3.0, and SRK/T. Both standard and total keratometry from the IOLMaster 700 and standard keratometry from the Anterion were used for each formula. Results: Constant optimization provided slightly different values for the A-constant, which ranged between 118.99 and 119.16, depending on the formula and the optical biometer. According to the heteroscedastic test, within each keratometry modality the standard deviation of the SRK/T was significantly higher compared to that of the Holladay 1, Kane, Olsen, and RBF 3.0 formulas. The SRK/T formula provided less accurate results also when the absolute prediction errors were compared by Friedman test. According to McNemar's test with Holm corrections, statistically significant differences were found within each keratometry modality between the percentage of eyes with a prediction error within ±0.25 diopters obtained with the Olsen formula compared to the Holladay 1 and Hoffer Q formulas. Conclusions: Constant optimization remains a mandatory step to achieve the best outcomes with the new EDOF IOL: the same constant should not be used for all formulas and for both optical biometers. Different statistical tests revealed that older IOL formulas have lower accuracy compared to newer formulas. [ J Refract Surg . 2023;39(3):158–164.]

Publisher

SLACK, Inc.

Subject

Ophthalmology,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3