Changes in Light Disturbance Analyzer Evaluation in SMILE for High Myopia and Astigmatism

Author:

Reinstein Dan Z.,Archer Timothy J.,González-Méijome José Manuel,Vida Ryan S.,Gupta Ruchi

Abstract

PURPOSE: To study the objective change in light disturbance around a glare source using the Light Disturbance Analyzer (LDA) (Binarytarget Lda) and correlate this with the validated subjective quality of vision (QoV) questionnaire in small incision lenticule extraction (SMILE) for high compound myopic astigmatism. METHODS: This was a prospective study recruiting 114 patients undergoing SMILE with attempted spherical equivalent refraction (SEQ) correction from −9.00 to −13.00 diopters (D), and cylinder up to 5.00 D. The LDA was used before and 3 and 12 months after surgery to evaluate the Light Disturbance Area, Light Disturbance Index, Best Fit Circle Radius, and Best Fit Circle Irregularity. Patients completed the Rasch-validated QoV questionnaire before and 12 months after surgery. Correlation analysis was performed between the LDA parameters and the QoV frequency, severity, and bothersomeness for halos and starbursts. RESULTS: At 12 months, there was a non-statistically signifcant change of 11.9% for Light Disturbance Area and Light Disturbance Index and 6.5% for Best Fit Circle Radius. There was an increase of 81.9% for Best Fit Circle Irregularity ( P = .017). Light Disturbance Area, Light Disturbance Index, and Best Fit Circle Radius correlated with bothersomeness for QoV halos, and with frequency, severity and bothersomeness for QoV star-bursts (P < .05), albeit with a low correlation coefficient ( R 2 < 0.13). There was no correlation between increase in Best Fit Circle Irregularity and the halo and starburst scores from the QoV questionnaire. CONCLUSIONS: LDA Best Fit Circle Irregularity was found to increase following high myopic SMILE. Other LDA parameters appeared to increase, but a much larger sample would be required to find statistical significance. The change in LDA parameters was only weakly correlated with QoV halo and starburst metrics, representing the wide variation in inter-subject perception. [ J Refract Surg . 2022;38(11):725–732.]

Publisher

SLACK, Inc.

Subject

Ophthalmology,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3