Comparison Between the Wavefront-Optimized and Custom-Q Aspheric Ablation Profiles in Myopic Eyes With Two Different Q-targets: A Contralateral Eye Study

Author:

González-Cruces Timoteo,Villarrubia Alberto,Sánchez Ventosa Álvaro,Palacín Miranda Elisa,Castillo Eslava Rosa,Gomera Martinez Aurora,García Párrizas José Alberto,Torres Huelva Pablo,Sánchez-González Jose María,Cano-Ortiz Antonio

Abstract

PURPOSE: To compare two aspheric ablation profiles in myopic refractive surgery using different asphericity targets. METHODS: Patients underwent laser in situ keratomileusis (LASIK) with the WaveLight EX500 laser platform (Alcon, WaveLight Laser Technologie). Asymmetric surgery was performed, programming the wavefront-optimized (WFO) ablation profile in one eye and the custom-Q (CQ) profile in the contralateral eye. The patients were divided into two groups following a systematic randomization method. The Q-target programmed for the preoperative Q group was equal to the preoperative asphericity of the CQ profile, and for the −0.6 Q-target group, the Q-target was set to −0.6. RESULTS: The study included 100 patients (200 eyes). Both groups had comparable safety and efficacy indexes greater than 1. A similar oblate shift in postoperative asphericity was seen in both groups regardless of the ablation profile and programmed Q-target. Asphericity was 0.33 ± 0.34 and 0.35 ± 0.29 ( P = .18) in the preoperative Q group and 0.26 ± 0.28 and 0.26 ± 0.27 ( P = .89) in the −0.6 Q-target group for WFO and CQ, respectively. A lower spherical aberration was found with CQ compared to WFO when the Q-target was set to −0.6: 0.211 ± 0.121 versus 0.144 ± 0.114 ( P < .01). However, no statistically significant differences were found when the preoperative Q-target was used. CONCLUSIONS: WFO and CQ treatments are similar in terms of refractive and visual outcomes. CQ offers greater control over the increase in positive spherical aberration after myopic refractive surgery, but it does not represent an advantage over WFO in the oblate shift in postoperative asphericity regardless of the Q-target programmed. [ J Refract Surg . 2022;38(11):698–707.]

Publisher

SLACK, Inc.

Subject

Ophthalmology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3