Aneurysm characteristics, coil packing, and post-coiling hemodynamics affect long-term treatment outcome

Author:

Damiano Robert JORCID,Tutino Vincent MORCID,Paliwal NikhilORCID,Patel Tatsat RORCID,Waqas MuhammadORCID,Levy Elad IORCID,Davies Jason MORCID,Siddiqui Adnan HORCID,Meng HuiORCID

Abstract

BackgroundRecurrence of intracranial aneurysms after endovascular coiling is a serious clinical concern.ObjectiveWe hypothesized that recurrence is associated with aneurysm morphology and flow, as well as the coil intervention and the induced flow modifications.MethodsWe collected 52 primary-coiling aneurysm cases that were either occluded (n=34) or recurrent (n=18) at >1 year follow-up. We created aneurysm models from pre-coiling digital subtraction angiographic images, calculated aneurysm morphology, simulated pre-coiling hemodynamics, modeled coil deployment, and obtained post-coiling hemodynamics for each case. We performed univariable analysis on 26 morphologic, treatment-specific, and hemodynamic parameters to distinguish between recurrent and occluded groups, and multivariable analysis to identify independently significant parameters associated with recurrence. Univariable analysis was also performed on ruptured and unruptured aneurysm subcohorts separately to investigate if they shared specific significant parameters.ResultsRecurrence was associated with pre-coiling aneurysm morphologic and flow parameters including larger size (maximum dimension and volume), larger neck (diameter, area, and neck-to-parent-artery ratio), and higher flow momentum and kinetic energy. Recurrence was also associated with lower coil packing (packing density and uncoiled volume), higher post-treatment flow (velocity, momentum, and kinetic energy), lower post-treatment washout time, and higher post-treatment impingement force at the neck. Multivariable analysis identified two aneurysmal characteristics (neck diameter and pre-coiling flow kinetic energy), one coil packing parameter (uncoiled volume), and one post-treatment hemodynamic parameter (flow momentum) that were independently associated with recurrence. In ruptured aneurysms, recurrence was associated with larger neck (diameter and area), whereas in unruptured aneurysms, recurrence was associated with larger size (maximum dimension and volume). In both subcohorts, recurrence was associated with higher post-coiling flow momentum and kinetic energy.ConclusionRecurrence at >1 year after coil treatment is associated with intrinsic aneurysm characteristics, coiling itself, and flow changes induced by coiling. Larger aneurysm size and neck, less coil packing, and higher intra-aneurysmal flow before and after coiling predict recurrence.

Funder

National Institute of Neurological Disorders and Stroke

Canon Medical Systems Corporation

Publisher

BMJ

Subject

Clinical Neurology,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3