Validation of a new method for saliva cortisol testing to assess stress in first responders

Author:

Smeets Math MJ,Vandenbossche Piet,Duijst Wilma LJM,Mook Walther NKA van,Leers Mathie P.G.ORCID

Abstract

BackgroundAcute or chronic stress can lead to physical and mental disorders. Measuring cortisol can objectify the degree of stress. Cortisol is traditionally measured in serum, but recently the relevant fraction of free cortisol can be reliably measured in saliva, using the very sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method. The use of saliva is non-invasive and allows easy serial testing around stressful events. The main objective of this study is to investigate whether serial saliva cortisol determinations using the LC-MS/MS method can be used to assess the stress response that first responders may experience during moments of acute professional deployment in their daily work.MethodsHealthy first responders (police officers, firefighters, rapid response team, ambulance personnel, first aid and emergency medical personnel) were recruited to participate in a Euregional high-reliability simulation training (‘Be Aware’-scenario training, 19 April 2018). At three time points, simultaneous venous blood samples and saliva samples were obtained. These time points were 1 hour before, immediately after and 10 hours after the simulation training. The correlation between changes in saliva cortisol measured by LC-MS/MS and serum cortisol at all three time points was determined. Results were compared with spectators not directly participating in the simulation.Results70 subjects participated in the simulation. There was a strong correlation between the changes in saliva and blood cortisol at the three time points. A significant increase in blood and saliva cortisol was shown 1 hour after the experienced stress moments. The levels had almost completely returned to baseline in all healthy volunteers 10 hours later. Cortisol in spectators was unaffected.ConclusionSerial saliva cortisol measurements using LC-MS/MS is a reliable and fast non-invasive functional stress assay, which can be easily collected in daily practice and used for investigation and monitoring of stress response in front line responders.

Publisher

BMJ

Subject

Critical Care and Intensive Care Medicine,General Medicine,Emergency Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3