Background/aimsTo propose and validate a new pterygium grading system based on slit-lamp evaluation.MethodsThis prospective cross-sectional study included 217 patients with pterygium. All patients underwent slit-lamp examination, and slit-lamp photographs were independently graded by two graders twice. A total of eight parameters were evaluated and all parameters were assigned with a score of 1–4 (normal–severe). Intra-rater and inter-rater reliability as determined by weighted Cohen’s kappa analysis.ResultsA total of 868 independent assessment, based on 217 slit-lamp images, were performed by two graders. For conjunctival assessment, the intra-rater reliability was excellent for body thickness (κ=0.81–0.89) and size at limbus (κ=0.87–0.92), substantial-to-excellent for body vascularity (κ=0.72–0.86), and moderate-to-excellent for body length (κ=0.57–0.81), whereas the inter-rater reliability was excellent for size at limbus (κ=0.86), substantial for body thickness (κ=0.72–0.73) and body vascularity (κ=0.66–0.75), and moderate for body length (κ=0.54–0.57). For corneal assessment, the intra-rater reliability was excellent for all four parameters (κ=0.84–0.90) whereas the inter-rater reliability was excellent for head length (κ=0.86–0.87), substantial-to-excellent for head vascularity (κ=0.78–0.82), substantial for Stocker’s line (κ=0.79–0.80) and head thickness (κ=0.67–0.69). The grading system was named SLIT2, which included Stocker’s line, Size at limbus, Length of head/body, Injection/vascularity of body/head, and Thickness of body/head.ConclusionThe proposed SLIT2 grading system, consisting of eight components, may serve as a reliable tool to standardise the reporting of pterygium severity and disease recurrence for clinical and research applications.

Publisher

BMJ

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3