Systematic Review of Acupuncture Placebo Devices with a Focus on the Credibility of Blinding of Healthy Participants And/Or Acupuncturists

Author:

Zhang George Shengxi1,Zhang Claire Shuiqing1,Tan Hsiewe Ying12,Wang Yanyi1,DaCosta Cliff3,Zhang Anthony Lin1,Xue Charlie Changli1,Xie Yi Min4

Affiliation:

1. School of Health and Biomedical Sciences, RMIT University, Bundoora, Victoria, Australia

2. School of Science and Health, Western Sydney University, Sydney, New South Wales, Australia

3. School of Sciences, RMIT University, Bundoora, Victoria, Australia

4. Centre for Innovative Structures and Materials, School of Engineering, RMIT University, Melbourne, Victoria, Australia

Abstract

Background An ideal placebo design in clinical research should resemble the intervention under investigation to facilitate blinding, yet remain clinically inert. With regard to physical interventions such as acupuncture, a true placebo device has not been developed and validated. Since 1998, researchers have designed several placebo acupuncture devices (PADs). The three most widely used PADs are the Streitberger, the Park and the Takakura device. Aim This review focuses on evaluating studies of these devices, in the context of credibility of blinding (COB), assessment of penetrating pain or sensation, and de qi sensation. Methods Electronic database searches were conducted in four English and two Chinese databases from their inception until November 2016. All studies included in the review were conducted on healthy participants and compared verum manual acupuncture with any of the aforementioned PADs with respect to one or more of the above three outcomes related to blinding effect. Results The synthesised analyses of the 15 included studies showed that the Streitberger and Park placebo devices may not blind participants successfully when tested at a sensitive acupuncture point (LI4). In terms of penetrating sensation, there were significant differences between these two placebo devices and verum acupuncture when applied at this point. The Takakura device was the only PAD that had the potential to blind the acupuncturist. However, the blinding analyses of all outcome measures were inconsistent. Conclusion Overall, there were insufficient data to confirm the blinding effects of these skin-contact PADs as each device was associated with limitations that warrant further design improvements.

Publisher

SAGE Publications

Subject

Neurology (clinical),Complementary and alternative medicine,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3