Liberación de aluminio de tres selladores endodónticos biocerámicos. Un ensayo in vitro //Aluminum release from three bioceramic endodontic sealers. An in vitro test

Author:

Leonhardt AlejandroORCID,Paduli NicolásORCID,Zmener OsvaldoORCID,Chantiri MiguelORCID,Della Porta RobertoORCID

Abstract

Objetivos: Determinar y comparar la liberación de aluminio (Al) a partir de la formulación química de los selladores endodónticos biocerámicos Bio-C® Sealer, AHPlus® Biocerámico y BioLine Sealer Z. Materiales y métodos: Se prepararon cinco (n=5) muestras de cada uno de los materiales y se determinó el contenido de Al liberado mediante espectrometría de masa con plasma inductivo acoplado ICP-MS. Los resultados se analizaron mediante ANOVA y la prueba de comparación múltiple de Tukey con un nivel de significación de 0,05. Resultados: La proporción de Al liberado por los selladores biocerámicos analizados fue de 0,04 mg/g para Bio-C® Sealer y BioLine Sealer Z y de 0,0012 mg/g para AHPlus® Bioceramic Sealer. ANOVA mostró un nivel significativo para el factor material (p<0,0001). La prueba de Tukey reveló que la liberación de Al de AHPlus®Bioceramic Sealer, fue significativamente menor a la de los otros dos selladores (p<0,05). Conclusión: La proporción de Al liberado por AHPlus® Bioceramic Sealer es menor que Bio-C® Sealer y BioLine Sealer Z. Si bien los tres selladores liberaron Al, ninguno de los valores superó aquellos de la ingesta media diaria de un individuo adulto, por lo que no representaría un riesgo biológico para su uso clínico en humanos. Palabras clave: Aluminio, endodoncia, selladores biocerámicos, silicato de calcio. //Aim: Determine and compare the lease of aluminum (Al) from three bioceramic endodontic sealers Bio- C® Sealer, AHPlus ® Bioceramic Sealer and BioLine Sealer Z. Materials and methods: Five (n=5) samples of each of the materials were prepared and the released Al content was determined by mass spectrometry with inductively coupled plasma ICP-MS. The results were analyzed with ANOVA and Tukey´s multiple comparison test with a significance level of p<0.05. Results: The proportion of Al released by the bioceramic sealers analyzed was 0.04 mg/g for Bio-C® Sealer and BioLine Sealer Z, and 0.0012 mg/g for AH Plus® Bioceramic Sealer. ANOVA showed a significant level for the factor material (p<0.0001). Tukey’s test revealed that the Al release from AH Plus® Bioceramic Sealer was significantly lower than that of the other two sealers (p<0.05). Conclusions: The proportion of Al released by AH Plus® Bioceramic Sealer is lower than that of Bio-C® Sealer and BioLine Sealer Z. Although all three sealers released Al, none of the values exceeded the average daily intake for an adult individual, and therefore, they would not represent a biologic risk for clinical use in humans. Keywords: Aluminum, bioceramic sealers, calcium silicate, endodontics.

Publisher

Asociacion Odontologica Argentina

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.7亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2025 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3