Study on the transferability of the knowledge-based VMAT model to predict IMRT plans in prostate cancer radiotherapy

Author:

Bi Suyan,Sun Xingru,Sohaimi Wan Fatihah Binti Wan,Yusoff Ahmad Lutfi Bin

Abstract

Abstract Objective The aim of this study was to investigate the feasibility of VMAT library-derived model transfer in the prediction of IMRT plans by dosimetry comparison among with three groups of IMRT plans: two groups of automatic IMRT plans generated by the knowledge-based the volumetric modulated arc therapy (VMAT) model and intensity-modulated radiation therapy (IMRT) model and one group of manual IMRT plans. Methods 52 prostate cancer patients who had completed radiotherapy were selected and randomly divided into 2 groups with 40 and 12 separately. Then both VMAT and IMRT plans were manually designed for all patients. The total plans in the group with 40 cases as training datasets were added to the knowledge-based planning (KBP) models for learning and finally obtained VMAT and IMRT training models. Another 12 cases were selected as the validation group to be used to generated auto IMRT plans by KBP VMAT and IMRT models. At last, the radiotherapy plans from three groups were obtained: the automated IMRT plan (V-IMRT) predicted by the VMAT model, the automated IMRT plan (I-IMRT) predicted by the IMRT model and the manual IMRT plan (M-IMRT) designed before. The dosimetric parameters of planning target volume (PTV) and organ at risks (OARs) as well as the time parameters (monitor unit, MU) were statistically analyzed. Results The dose limit of all plans in the training datasets met the clinical requirements. Compared with the training plans added to VMAT model, the dosimetry parameters have no statistical differences in PTV (P > 0.05); the dose of X% volume (Dx%) with D25% and D35% in rectal and the maximum dose (Dmax) in the right femoral head were lower (P = 0.04, P = 0.01, P = 0.00) while D50% in rectal was higher (< 0.05) in the IMRT model plans. In the 12 validation cases, both automated plans showed better dose distribution compared with the M-IMRT plan: the Dmax of PTV in the I-IMRT plans and the dose in volume of interesting (VOI) of bladder and bilateral femoral heads were lower with a statistically significant difference (P < 0.05). Compared with the I-IMRT plans, dosimetric parameters in PTV and VOI of all OARs had no statistically significant differences (P > 0.05), but the Dmax in left femoral heard and D15% in the right femoral head were lower and have significant differences (P < 0.05). Furthermore, the low-dose regions, which was defined as all volumes outside of the PTV (RV) with the statistical parameters of mean dose (Dmean), the volume of covering more than 5 Gy dose (V5Gy), and also the time parameter (MU) required to perform the plan were considered. The results showed that Dmean in V-IMRT was smaller than that in the I-IMRT plan (P = 0.02) and there was no significant difference in V5Gy and MU (P > 0.05). Conclusion Compared with the manual plan, the IMRT plans generated by the KBP models had a significant advantage in dose control of both OARs and PTV. Compared to the I-IMRT plans, the V-IMRT plans was not only without significant disadvantages, but it also achieved slightly better control of the low-dose region, which meet the clinical requirements and can used in the clinical treatment. This study demonstrates that it is feasible to transfer the KBP VMAT model in the prediction of IMRT plans.

Funder

Youth Start-up Fund of Shenzhen Cancer Hospital

Shenzhen Key Medical Discipline Construction Fund

Publisher

Springer Science and Business Media LLC

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3