Association of elastic power in mechanical ventilation with the severity of acute respiratory distress syndrome: a retrospective study

Author:

Xie Yongpeng,Shi Jiaxin,Liu Suxia,Chen Xiaobing,Wang Yanli,Li Xiaomin,Yan Yao

Abstract

Abstract Background Mechanical power (MP) is the total energy released into the entire respiratory system per minute which mainly comprises three components: elastic static power, Elastic dynamic power and resistive power. However, the energy to overcome resistance to the gas flow is not the key factor in causing lung injury, but the elastic power (EP) which generates the baseline stretch of the lung fibers and overcomes respiratory system elastance may be closely related to the ARDS severity. Thus, this study aimed to investigate whether EP is superior to other ventilator variables for predicting the severity of lung injury in ARDS patients. Methods We retrieved patient data from the Medical Information Mart for Intensive Care III (MIMIC-III) database. The retrieved data involved adults (≥ 18 years) diagnosed with ARDS and subjected to invasive mechanical ventilation for ≥ 48 h. We employed univariate and multivariate logistic regression analyses to investigate the correlation between EP and development of moderate-severe ARDS. Furthermore, we utilized restricted cubic spline models to assess whether there is a linear association between EP and incidence of moderate-severe ARDS. In addition, we employed a stratified linear regression model and likelihood ratio test in subgroups to identify potential modifications and interactions. Results Moderate-severe ARDS occurred in 73.4% (296/403) of the patients analyzed. EP and MP were significantly associated with moderate-severe ARDS (odds ratio [OR] 1.21, 95% confidence interval [CI] 1.15–1.28, p < 0.001; and OR 1.15, 95%CI 1.11–1.20, p < 0.001; respectively), but EP showed a higher area-under-curve (95%CI 0.72–0.82, p < 0.001) than plateau pressure, driving pressure, and static lung compliance in predicting ARDS severity. The optimal cutoff value for EP was 14.6 J/min with a sensitivity of 75% and specificity of 66%. Quartile analysis revealed that the relationship between EP and ARDS severity remained robust and reliable in subgroup analysis. Conclusion EP is a good ventilator variable associated with ARDS severity and can be used for grading ARDS severity. Close monitoring of EP is advised in patients undergoing mechanical ventilation. Additional experimental trials are needed to investigate whether adjusting ventilator variables according to EP can yield significant improvements in clinical outcomes.

Publisher

Springer Science and Business Media LLC

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3