Impact of framing scheme optimization and smoking status on binding potential analysis in dynamic PET with [11C]ABP688

Author:

Régio Brambilla CláudiaORCID,Scheins Jürgen,Tellmann Lutz,Issa Ahlam,Herzog Hans,Shah N. Jon,Neuner Irene,Lerche Christoph W.

Abstract

Abstract Background For positron emission tomography (PET) ligands, such as [11C]ABP688, to be able to provide more evidence about the glutamatergic hypothesis in schizophrenia (SZ), quantification bias during dynamic PET studies and its propagation into the estimated values of non-displaceable binding potential (BPND) must be addressed. This would enable more accurate quantification during bolus + infusion (BI) neuroreceptor studies and further our understanding of neurological diseases. Previous studies have shown BPND-related biases can often occur due to overestimated cerebellum activity (reference region). This work investigates whether an alternative framing scheme can minimize quantification biases propagated into BPND, whether confounders, such as smoking status, need to be controlled for during the study, and what the consequences for the data interpretation following analysis are. A group of healthy controls (HC) and a group of SZ patients (balanced and unbalanced number of smokers) were investigated with [11C]ABP688 and a BI protocol. Possible differences in BPND quantification as a function of smoking status were tested with constant 5 min (‘Const 5 min’) and constant true counts (‘Const Trues’) framing schemes. In order to find biomarkers for SZ, the differences in smoking effects were compared between groups. The normalized BPND and the balanced number of smokers and non-smokers for both framing schemes were evaluated. Results When applying F-tests to the ‘Const 5 min’ framing scheme, effect sizes (η2p) and brain regions which showed significant effects fluctuated considerably with F = 50.106 ± 54.948 (9.389 to 112.607), P-values 0.005 to < 0.001 and η2p = 0.514 ± 0.282 (0.238 to 0.801). Conversely, when the ‘Const Trues’ framing scheme was applied, the results showed much smaller fluctuations with F = 78.038 ± 8.975 (86.450 to 68.590), P < 0.001 for all conditions and η2p = 0.730 ± 0.017 (0.742 to 0.710), and regions with significant effects were more robustly reproduced. Further, differences, which would indicate false positive identifications between HC and SZ groups in five brain regions when using the ‘Const 5 min’ framing scheme, were not observed with the ‘Const Trues’ framing. Conclusions Based on an [11C]ABP688 PET study in SZ patients, the results show that non-consistent BPND outcomes can be propagated by the framing scheme and that potential bias can be minimized using ‘Const Trues’ framing.

Funder

Deutsche Forschungsgemeinschaft

FP7 Health

Forschungszentrum Jülich GmbH

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3