Preoperative planning by osteotomy master software helps to improve the accuracy of target limb alignment in high tibial osteotomy

Author:

He Axiang,Mao Yanjie,Zhou Ying,Kong Qin,zhang Hui,Chen Yanan,Liu Wanjun,Zhang Xianlong

Abstract

AbstractBackgroundThe accuracy of targeted lower limb alignment correction following HTO is closely related to patients’ pain relief and knee joint survival time. How to accurately perform osteotomy and how to obtain the ideal target limb alignment to maximize the curative effect are the difficulty in HTO practice. The purpose of this study is to evaluate the predictive and application value of osteotomy master software (OsteoMaster) in coronal plane preoperative planning of high tibial osteotomy.MethodSixty-seven patients with medial compartment osteoarthritis and varus deformity treated by medial open-weight high tibial osteotomy were enrolled and divided into observation group (31 cases) and control group (36 cases). The observation group was planned by OsteoMaster, while the control group was planned by Miniaci. The preoperative predicted values of osteotomy depth, open height, correction angle, WBL ratio, and FTA of the observation group were compared with the actual intraoperative values to study their accuracy. The operative time, blood loss, number of fluoroscopy, and WBL ratio were compared between the observation group and the control group to study its application value.ResultThere was no significant difference between two groups in preoperative prediction and intraoperative reality of osteotomy depth, open height, correction angle, FTA, and WBL ratio (P> 0.05). The operation time and number of fluoroscopy in the observation group were significantly less than those in the control group (P< 0.05), while the difference in blood loss was not statistically significant (P> 0.05). The good rate of WBL ratio was 87.1% in the observation group and 75% in the control group.ConclusionOsteoMaster has predictive value in osteotomy depth, open height, correction angle, FTA, and WBL ratio of HTO, which is also helpful to reduce the number of fluoroscopy, shorten the operation time, and improve the accuracy of target limb alignment. The drawback of this approach is 2-dimensional approach in contrast to 3-dimensional preoperative planning that is including the more real study.

Funder

Shanghai Health and Hygiene Commission " Healthy aging" program

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3