Effect analysis of medial bracing plate combined with cannulated screw in unstable femoral neck fracture assisted by surgical hip dislocation: a retrospective study

Author:

Sun Xin,Yi Gang,Ao Liang,Zhou Xin,Zhang Tao,Guan Tai-yuan

Abstract

Abstract Background Unstable femoral neck fractures have a high likelihood of causing severe disruption to the blood supply. This study aimed to assess the therapeutic effect of surgical hip dislocation using a medial support plate combined with cannulated screw fixation for the treatment of unstable femoral neck fractures in young and middle-aged adults. Methods We retrospectively analyzed the medical records of 68 young adults who underwent internal fixation of unstable femoral neck fractures. The observation group included 32 patients who had received medial support plate and cannulated screw fixation by the surgical hip dislocation method and 36 patients who had undergone anti-rotation screw composite compression system fixation comprised the comparison group. The amount of intraoperative bleeding, surgery duration, fracture recovery time and complications were recorded. The degree of femoral neck shortening and Garden index were assessed using the Zlowodzki method. Additionally, hip functionality was evaluated using the Harris score at 3 and 6 months and at the last follow-up. Results All 68 patients in both groups were followed up for 12–42 months (mean, 22.4 months). The postoperative incision was well-aligned and no inflation was observed. The intraoperative blood loss and surgery duration in the comparison group were longer than those in the observation. Additionally, the observation group had a significantly shorter fracture recovery time and a higher Garden index than the comparison at 6 months postoperatively; however, there was no significant statistical discrepancy between the two groups at the remaining time points. The observation group had higher Harris scores than the comparison at 3 and 6 months postoperatively. Conclusion Surgical hip dislocation applied to the medial support plate combined with cannulated screw fixation has clinical application value in restoring the stability of femoral neck fractures while facilitating the maintenance of blood flow to the femoral head and neck.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3