Identification of safe channels for screws in the anterior pelvic ring fixation system

Author:

Liu Lin,Fan Shicai,Zeng Donggui,Song Hui,Zeng Letian,Wen Xiangyuan,Jin Dadi

Abstract

Abstract Background Minimally invasive surgery for pelvic fracture using anterior ring internal fixator system is increasing gradually, and the way to insert the fixation screws in the fixation system is the key technical points of the method. However, there have been few studies on insertion of fixation screws for the anterior pelvic ring internal fixator system. Objective To identify safe channels for fixation screws in the anterior pelvic fixator system and provide the anatomical basis for insertion of fixation screws in clinical operation. Methods Screw insertion was simulated into a total of 40 pelvic finite element models as well as 16 fresh pelvic specimens, and the channel parameters were measured. Results Finite elements (male, female) include: screws in ilium: length 114.4 ± 4.1 and 107.6 ± 8.3 mm, respectively; diameter 11.7 ± 0.5 and 10.0 ± 0.6 mm, distance between screw and anterior inferior iliac spine: 5.5 ± 1.0 and 5.6 ± 1.0 mm, angle of coronal plane 55.8° ± 2.4° and 50.6° ± 3.1°, angle of sagittal plane 26.6° ± 1.0° and 24.5° ± 1.9° and angle of horizontal plane 64.9 ± 3.7 and 58.1 ± 3.1; screws in pubis: length 47.0 ± 2.0 and 39.8 ± 3.9 mm, diameter 7.1 ± 0.4 and 6.1 ± 0.4 mm. Specimens (male, female) include: distance between screw and anterior inferior iliac spine: 5.5 ± 0.5 and 5.6 ± 0.7 mm, angle of coronal plane 55.9° ± 1.3° and 50.7° ± 1.5°, angle of sagittal plane 26.7° ± 0.5° and 24.1° ± 0.9° and angle of horizontal plane 64.8° ± 0.6° and 58.8° ± 0.8°. In the comparison between female and male in each group, differences in distances between screws and anterior inferior iliac spine and median line of symphysis pubis (P > 0.05) were not statistically significant; differences in the remaining parameters were statistically significant (P < 0.05). Conclusions If surgeons paid attention to sex differences, select screws of appropriate diameter and length and hold the insertion position and direction, screws in the anterior pelvic ring fixation system could be safely inserted.

Funder

economic development of Guangming District, Shenzhen, China

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3