Abstract
Abstract
Background
Minimally invasive surgery is becoming more common and transfemoral transcatheter aortic valve replacement is offered to older patients with multiple comorbidities. Sternotomy is not required but patients must lie flat and still for up to 2–3 h. This procedure is increasingly being performed under conscious sedation with supplementary oxygen, but hypoxia and agitation are commonly observed.
Methods
In this randomised controlled trial, we hypothesised that high-flow nasal oxygen would provide superior oxygenation as compared with our standard practice, 2 l min−1 oxygen by dry nasal specs. This was administered using the Optiflow THRIVE Nasal High Flow delivery system (Fisher and Paykel, Auckland, New Zealand) at a flow rate of 50 l min−1 and FiO2 0.3. The primary endpoint was the change in arterial partial pressure of oxygen (pO2) during the procedure. Secondary outcomes included the incidence of oxygen desaturation, airway interventions, the number of times the patient reached for the oxygen delivery device, incidence of cerebral desaturation, peri-operative oxygen therapy duration, hospital length of stay and patient satisfaction scores.
Results
A total of 72 patients were recruited. There was no difference in change in pO2 from baseline using high-flow compared with standard oxygen therapy: median [IQR] increase from 12.10 (10.05–15.22 [7.2–29.8]) to 13.69 (10.85–18.38 [8.5–32.3]) kPa vs. decrease from 15.45 (12.17–19.33 [9.2–22.8]) to 14.20 (11.80–19.40 [9.7–35.1]) kPa, respectively. The percentage change in pO2 after 30 min was also not significantly different between the two groups (p = 0.171). There was a lower incidence of oxygen desaturation in the high-flow group (p = 0.027). Patients in the high-flow group assigned a significantly higher comfort score to their treatment (p ≤ 0.001).
Conclusion
This study has demonstrated that high flow, compared with standard oxygen therapy, does not improve arterial oxygenation over the course of the procedure. There are suggestions that it may improve the secondary outcomes studied.
Trial registration
International Standard Randomised Controlled Trial Number (ISRCTN) 13,804,861. Registered on 15 April 2019. https://doi.org/10.1186/ISRCTN13804861
Funder
Fisher and Paykal Healthcare
Publisher
Springer Science and Business Media LLC
Reference38 articles.
1. Balanika M, Smyrli A, Samanidis G, et al. Anesthetic management of patients undergoing transcatheter aortic valve implantation. J Cardiothorac Vasc Anesth. 2014;28:285–9.
2. Baumgartner H, Falk V, Bax JJ, et al. 2017 ESC/EACTS Guidelines for the Management of Valvular Heart Disease. Rev Esp Cardiol. 2018;71:110.
3. Ben-Menachem E, McKenzie J, O’Sullivan C, Havryk AP. High-flow nasal oxygen versus standard oxygen during flexible bronchoscopy in lung transplant patients: a randomized controlled trial. Journal of Bronchology and Interventional Pulmonology. 2020;27:259–65.
4. Carratalá Perales JM, Llorens P, Brouzet B, et al. High-Flow therapy via nasal cannula in acute heart failure. Rev Esp Cardiol. 2011;64:723–5.
5. Chanques G, Riboulet F, Molinari N, et al. Comparison of three high flow oxygen therapy delivery devices: a clinical physiological cross-over study. Minerva Anestesiol. 2013;79:1344–55.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献