Abstract
Abstract
Purpose
To assess the outcome [zygomatic implant (ZI) survival] and complications of the original surgical technique (OST) and an Anatomy-Guided approach (AGA) in the placement of ZI in patients with severely atrophic maxillae.
Methods
Two independent reviewers conducted an electronic literature search from January 2000 to August 2022. The inclusion criteria were articles reporting at least five patients with severely atrophic edentulous maxilla undergoing placement OST and/or AGA, with a minimum of 6 months of follow-up. Number of patients, defect characteristics, number of ZI, implant details, surgical technique, survival rate, loading protocol, prosthetic rehabilitation, complications, and follow-up period were compared.
Results
Twenty-four studies comprised 2194 ZI in 918 patients with 41 failures. The ZI survival rate was 90.3–100% in OST and 90.4–100% in AGA. Probability of complications with ZI with OST was as follows: sinusitis, 9.53%; soft tissue infection, 7.50%; paresthesia, 10.78%; oroantral fistulas, 4.58%; and direct surgical complication, 6.91%. With AGA, the presenting complications were as follows: sinusitis, 4.39%; soft tissue infection, 4.35%; paresthesia, 0.55%; oroantral fistulas, 1.71%; and direct surgical complication, 1.60%. The prevalence of immediate loading protocol was 22.3% in OST and 89.6% in the AGA. Due to the heterogeneity of studies, statistical comparison was only possible after the descriptive analysis.
Conclusions
Based on the current systematic review, placing ZI in severely atrophic edentulous maxillae rehabilitation with the OST and AGA is associated with a high implant survival rate and surgical complications within a minimum of 6 months follow-up. Complications, including sinusitis and soft tissue infection around the implant, are the most common. The utilization of immediate loading protocol is more observed in AGA than in OST.
Graphical Abstract
Funder
Universitätsmedizin der Johannes Gutenberg-Universität Mainz
Publisher
Springer Science and Business Media LLC
Reference56 articles.
1. Bedrossian E. Rehabilitation of the edentulous maxilla with the zygoma concept: a 7-year prospective study. Int J Oral Maxillofac Implants. 2010;25(6):1213–21.
2. Brånemark PI, Gröndahl K, Ohrnell LO, Nilsson P, Petruson B, Svensson B, Engstrand P, Nannmark U. Zygoma fixture in the management of advanced atrophy of the maxilla: technique and long-term results. Scand J Plast Reconstr Surg Hand Surg. 2004;38(2):70–85.
3. Bedrossian E, Rangert B, Stumpel L, Indersano T. Immediate function with the zygomatic implant: a graftless solution for the patient with mild to advanced atrophy of the maxilla. Int J Oral Maxillofac Implants. 2006;21:937–42.
4. Chow J, Hui E, Lee PK, et al. Zygomatic implants—protocol for immediate occlusal loading: a preliminary report. J Oral Maxillofac Surg. 2006;64:804–11.
5. Davó R, David L. Quad zygoma: technique and realities. Oral Maxillofac Surg Clin N Am. 2019;31:285–97.
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献