Lung disease burden assessment by oscillometry in a systematically disadvantaged urban population experiencing homelessness or at-risk for homelessness in Ottawa, Canada from a prospective observational study

Author:

Pakhale Smita,Visentin Carly,Tariq Saania,Kaur Tina,Florence Kelly,Bignell Ted,Jama Sadia,Huynh Nina,Boyd Robert,Haddad Joanne,Alvarez Gonzalo G.

Abstract

Abstract Rationale Oscillometry is an emerging technique that offers some advantages over spirometry as it does not require forced exhalation and may detect early changes in respiratory pathology. Obstructive lung disease disproportionately impacts people experiencing homelessness with a high symptoms burden, yet oscillometry is not studied in this population. Objectives To assess lung disease and symptom burden using oscillometry in people experiencing homelessness or at-risk of homelessness using a community-based participatory action research approach (The Bridge Model™). Methods Of 80 recruited, 55 completed baseline oscillometry, 64 completed spirometry, and all completed patient-reported outcomes with demographics, health, and respiratory symptom related questionnaires in the Participatory Research in Ottawa: Management and Point-of-Care for Tobacco Dependence project. Using a two-tail t-test, we compared mean oscillometry values for airway resistance (R5–20), reactance area under the curve (Ax) and reactance at 5 Hz (X5) amongst individuals with fixed-ratio method (FEV1/FVC ratio < 0.70) and LLN (FEV1/FVC ratio ≤ LLN) spirometry diagnosed chronic obstructive pulmonary disease (COPD). We compared mean oscillometry parameters based on participants’ COPD assessment test (CAT) scores using ANOVA test. Results There was no significant difference between the pre- and post- bronchodilator values of R5–20 and Ax for the fixed ratio method (p = 0.63 and 0.43) and the LLN method (p = 0.45 and 0.36). There was a significant difference in all three of the oscillometry parameters, R5–20, Ax and X5, based on CAT score (p = 0.009, 0.007 and 0.05, respectively). There was a significant difference in R5–20 and Ax based on the presence of phlegm (p = 0.03 and 0.02, respectively) and the presence of wheeze (p = 0.05 and 0.01, respectively). Oscillometry data did not correlate with spirometry data, but it was associated with CAT scores and correlated with the presence of self-reported symptoms of phlegm and wheeze in this population. Conclusions Oscillometry is associated with respiratory symptom burden and highlights the need for future studies to generate more robust data regarding the use of oscillometry in systematically disadvantaged populations where disease burden is disproportionately higher than the general population. TrialRegistration: ClinicalTrails.gov—NCT03626064, Retrospective registered: August 2018, https://clinicaltrials.gov/ct2/show/NCT03626064

Funder

Champlain Local Health Integration Network

Department of Medicine and the Divisions of Respirology and Cardiology at the Ottawa Hospital

Publisher

Springer Science and Business Media LLC

Subject

Pulmonary and Respiratory Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3