Simultaneous dose distribution and fluence prediction for nasopharyngeal carcinoma IMRT

Author:

Li Yongbao,Cai Wenwen,Xiao Fan,Zhou Xuanru,Cai Jiajun,Zhou Linghong,Dou Wen,Song Ting

Abstract

Abstract Background Current intensity-modulated radiation therapy (IMRT) treatment planning is still a manual and time/resource consuming task, knowledge-based planning methods with appropriate predictions have been shown to enhance the plan quality consistency and improve planning efficiency. This study aims to develop a novel prediction framework to simultaneously predict dose distribution and fluence for nasopharyngeal carcinoma treated with IMRT, the predicted dose information and fluence can be used as the dose objectives and initial solution for an automatic IMRT plan optimization scheme, respectively. Methods We proposed a shared encoder network to simultaneously generate dose distribution and fluence maps. The same inputs (three-dimensional contours and CT images) were used for both dose distribution and fluence prediction. The model was trained with datasets of 340 nasopharyngeal carcinoma patients (260 cases for training, 40 cases for validation, 40 cases for testing) treated with nine-beam IMRT. The predicted fluence was then imported back to treatment planning system to generate the final deliverable plan. Predicted fluence accuracy was quantitatively evaluated within projected planning target volumes in beams-eye-view with 5 mm margin. The comparison between predicted doses, predicted fluence generated doses and ground truth doses were also conducted inside patient body. Results The proposed network successfully predicted similar dose distribution and fluence maps compared with ground truth. The quantitative evaluation showed that the pixel-based mean absolute error between predicted fluence and ground truth fluence was 0.53% ± 0.13%. The structural similarity index also showed high fluence similarity with values of 0.96 ± 0.02. Meanwhile, the difference in the clinical dose indices for most structures between predicted dose, predicted fluence generated dose and ground truth dose were less than 1 Gy. As a comparison, the predicted dose achieved better target dose coverage and dose hot spot than predicted fluence generated dose compared with ground truth dose. Conclusion We proposed an approach to predict 3D dose distribution and fluence maps simultaneously for nasopharyngeal carcinoma patients. Hence, the proposed method can be potentially integrated in a fast automatic plan generation scheme by using predicted dose as dose objectives and predicted fluence as a warm start.

Funder

Guangdong Basic and Applied Basic Research Foundation, China

Guangzhou Science and Technology Foundation, China

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3