Radiobiological and dosimetric comparison of 60Co versus 192Ir high-dose-rate intracavitary-interstitial brachytherapy for cervical cancer

Author:

Wen Aiping,Wang Xianliang,Wang Bingjie,Yan Chuanjun,Luo Jingyue,Wang Pei,Li Jie

Abstract

Abstract Background High-dose-rate (HDR) intracavitary-interstitial brachytherapy (IC-ISBT) is an effective treatment for bulky, middle, and advanced cervical cancer. In this study, we compared the differences between 60Co and 192Ir HDR IC-ISBT plans in terms of radiobiological and dosimetric parameters, providing a reference for clinical workers in brachytherapy. Methods A total of 30 patients with cervical cancer receiving HDR IC-ISBT were included in this study, and IC-ISBT plans for each individual were designed with both 60Co and 192Ir at a prescribed dose of CTV D90 = 6 Gy while keeping the dose to OARs as low as possible. Physical dose and dose–volume parameters of CTV and OARs were extracted from TPS. The EQD2, EUBED, EUD, TCP, and NTCP were calculated using corresponding formulas. The differences between the 60Co and 192Ir IC-ISBT plans were compared using the paired t-test. Results In each patient's 60Co and 192Ir IC-ISBT plan, the average physical dose and EQD2 of 60Co were lower than those of 192Ir, and there were statistically significant differences in D2cc and D1cc for the OARs (p < 0.05); there were statistically significant differences in D0.1 cc for the bladder (p < 0.05) and no significant differences in D0.1 cc for the rectum or intestines (p > 0.05). The EUBED ratio (60Co/192Ir) at the CTV was mostly close to 1 when neither 60Co or 192Ir passed their half-lives or when both passed two half-lives, and the difference between them was not significant; at the OARs, the mean value of 60Co was lower than that of 192Ir. There was no statistical difference between 60Co and 192Ir in the EUD (93.93 versus 93.92 Gy, p > 0.05) and TCP (97.07% versus 97.08%, p > 0.05) of the tumors. The mean NTCP value of 60Co was lower than that of 192Ir. Conclusions Considering the CTV and OARs, the dosimetric parameters of 60Co and 192Ir are comparable. Compared with 192Ir, the use of 60Co for HDR IC-ISBT can ensure a similar tumor control probability while providing better protection to the OARs. In addition, 60Co has obvious economic advantages and can be promoted as a good alternative to 192Ir.

Funder

Sichuan Science and Technology Program

Medical Engineering Innovation Fund for Cancer

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Oncology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3