Stereotactic body radiation therapy for prostate cancer: a study comparing 3-year genitourinary toxicity between CyberKnife and volumetric-modulated arc therapy by propensity score analysis

Author:

Ito Makoto,Yoshioka Yasuo,Takase Yuuki,Suzuki Junji,Takahashi Hironori,Minami Yoshitaka,Sakuragi Ami,Oshima Yukihiko,Okuda Takahito,Suzuki Kojiro

Abstract

Abstract Background To investigate whether the rate of stereotactic body radiation therapy-related (SBRT-related) genitourinary (GU) toxicity is lower in patients with prostate cancer treated with CyberKnife. Methods We retrospectively reviewed the medical records of patients with nonmetastatic prostate cancer at two institutions between 2017 and 2020. We analyzed 70 patients who were extracted by propensity score matching based on age, pre-treatment International Prostate Symptom Score (IPSS), and prostate volume. The patients were treated with SBRT, with a total dose of 36.25 Gy in five fractions over five consecutive weekdays, using CyberKnife or volumetric-modulated arc therapy (VMAT). Results The low-, medium-, and high-risk patients were 2, 19, and 14, respectively, in the CyberKnife group and 4, 17, and 14, respectively, in the VMAT group. The median follow-up time in both groups was 3 years. One patient with CyberKnife died of unrelated causes. No biochemical or clinical recurrence, distant metastases, or death from prostate cancer was observed. The peak values of IPSS in the acute phase (< 3 months) were significantly lower in the CyberKnife than in the VMAT group (CyberKnife:16.2 vs VMAT:20.2, p = 0.025). In multiple regression analyses, the treatment modality (p = 0.03), age (p = 0.01), bladder medication pre-irradiation (p = 0.03), and neoadjuvant androgen deprivation therapy (p = 0.04) contributed to the peak value of the acute-phase IPSS. The incidence of treatment-related grade 2 acute GU toxicity tended to be lower in the CyberKnife than the VMAT group (CyberKnife: 22.9% vs. VMAT: 45.7%, p = 0.077). No difference was noted between the groups with regard to late IPSS or GU toxicity and gastrointestinal toxicity in all phases. Toxicities of grade ≥ 3 have not been observed to date. Conclusions Regardless of treatment modality, SBRT is effective in treating prostate cancer without serious toxicity. However, CyberKnife has an advantage over VMAT in terms of acute prostate symptoms.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3