Effective contribution ratio of the molar during sequential distalization using clear aligners and micro-implant anchorage: a finite element study

Author:

Liu Xulin,Wu Junjie,Cheng Yuxun,Gao Jie,Wen Yi,Zhang Yubohan,Luo Houzhuo,Jin Zuolin,Ma YanningORCID

Abstract

Abstract Introduction This study aims to investigate the biomechanical effects of anchorage reinforcement using clear aligners (CAs) with microimplants during molar distalization. And also explores potential clinical strategies for enhancing anchorage in the sequential distalization process. Methods Finite element models were established to simulate the CAs, microimplants, upper dentition, periodontal ligament (PDL), and alveolar bone. In group set I, the 2nd molars underwent a distal movement of 0.25 mm in group set II, the 1st molars were distalized by 0.25 mm after the 2nd molars had been placed to a target position. Each group set consisted of three models: Model A served as the control model, Model B simulated the use of microimplants attached to the aligner through precision cuts, and Model C simulated the use of microimplants attached by buttons. Models B and C were subjected to a series of traction forces. We analyzed the effective contribution ratios of molar distalization, PDL hydrostatic stress, and von Mises stress of alveolar bone. Results The distalization of the 2nd molars accounted for a mere 52.86% of the 0.25-mm step distance without any reinforcement of anchorage. The remaining percentage was attributed to the mesial movement of anchorage teeth and other undesired movements. Models B and C exhibited an increased effective contribution ratio of molar distalization and a decreased loss of anchorage. However, there was a slight increase in the undesired movement of molar tipping and rotation. In group set II, the 2nd molar displayed a phenomenon of mesial relapse due to the reciprocal force produced by the 1st molar distalization. Moreover, the efficacy of molar distalization in terms of contribution ratio was found to be positively correlated with the magnitude of force applied. In cases where stronger anchorage reinforcement is required, precision cuts is the superior method. Conclusions The utilization of microimplants in conjunction with CAs can facilitate the effective contribution ratio of molar distalization. However, it is important to note that complete elimination of anchorage loss is not achievable. To mitigate undesired movement, careful planning of anchorage preparation and overcorrection is recommended.

Funder

The National Natural Science Foundation of China

The CSA Clinical Research Fund

The National Clinical Research Center for Oral Diseases

Key Research and Development Program of Shaanxi Province

New Technologies and New Business of School of Stomatology, Air Force Medical University Fund

College Science and Technology Innovation Plan of Shanxi Education Department

Publisher

Springer Science and Business Media LLC

Subject

Orthodontics

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Current status of the biomechanics of extra-alveolar miniscrews;Journal of the World Federation of Orthodontists;2024-02

2. Aligner biomechanics: Where we are now and where we are heading for;Journal of the World Federation of Orthodontists;2024-01