In vitro analysis and in vivo assessment of fracture complications associated with use of locking plate constructs for stabilization of caprine tibial segmental defects

Author:

Bowers Kristin M.ORCID,Wright Ellis M.,Terrones Lori D.,Sun Xiaocun,Rifkin Rebecca,Grzeskowiak Remi,Croy Elizabeth,Seddighi Reza,Kleine Stephanie,Hampton Chiara,Hecht Silke,Adair Henry S.,Anderson David E.,Mulon Pierre-Yves

Abstract

AbstractPurposeLocking plate fixation of caprine tibial segmental defects is widely utilized for translational modeling of human osteopathology, and it is a useful research model in tissue engineering and orthopedic biomaterials research due to its inherent stability while maintaining unobstructed visualization of the gap defect and associated healing. However, research regarding surgical technique and long-term complications associated with this fixation method are lacking. The goal of this study was to assess the effects of surgeon-selected factors including locking plate length, plate positioning, and relative extent of tibial coverage on fixation failure, in the form of postoperative fracture.MethodsIn vitro, the effect of plate length was evaluated using single cycle compressive load to failure mechanical testing of locking plate fixations of caprine tibial gap defects. In vivo, effects of plate length, positioning, and relative tibial coverage were evaluated using data from a population of goats enrolled in ongoing orthopedic research which utilized locking plate fixation of 2 cm tibial diaphyseal segmental defects to evaluate bone healing over 3, 6, 9, and 12 months.ResultsIn vitro, no significant differences in maximum compressive load or total strain were noted between fixations using 14 cm locking plates and 18 cm locking plates. In vivo, both plate length and tibial coverage ratio were significantly associated with postoperative fixation failure. The incidence of any cortical fracture in goats stabilized with a 14 cm plate was 57%, as compared with 3% in goats stabilized with an 18 cm plate. Craniocaudal and mediolateral angular positioning variables were not significantly associated with fixation failure. Decreasing distance between the gap defect and the proximal screw of the distal bone segment was associated with increased incidence of fracture, suggesting an effect on proximodistal positioning on overall fixation stability.ConclusionsThis study emphasizes the differences between in vitro modeling and in vivo application of surgical fixation methods, and, based on the in vivo results, maximization of plate-to-tibia coverage is recommended when using locking plate fixation of the goat tibial segmental defect as a model in orthopedic research.

Funder

U.S. Army Medical Research Acquisition Activity

Publisher

Wiley

Subject

Orthopedics and Sports Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3