Functional performance and patient satisfaction comparison between a 3D printed and a standard transradial prosthesis: a case report

Author:

Copeland Christopher,Reyes Claudia Cortes,Peck Jean L.,Srivastava Rakesh,Zuniga Jorge M.

Abstract

Abstract Background The delay between amputation and prosthesis fitting contributes to the high rate of prosthetic abandonment despite advances in technology. Three-dimensional (3D) printing has allowed for the rapid fabrication of prostheses. Allowing individuals with amputations to interact with a prosthesis shortly after their procedure may reduce rejection chances. The purpose of the current investigation is to compare functional outcomes and patient satisfaction between a standard transradial prosthesis fitted in a clinic with a 3D-printed prosthesis fitted remotely. The standard prosthesis featured a hook terminal device, while the 3D printed prosthesis’ terminal device was a functional hand. Results The main finding of this case study was that the use of a 3D printed arm prosthesis fitted remotely resulted in better functional performance, but lower overall patient satisfaction than the standard arm prosthesis. Use of the 3D printed arm resulted in improved gross manual dexterity as measured by the Box and Block test. The 3D printed prosthesis also allowed improved performance in bimanual coordination. However, the standard-hook device scored higher in patient satisfaction survey results. The patient's concerns with the 3D printed prosthesis were the durability and effectiveness of the device. Conclusion While durability and complex grip patterns remain a concern, the positive attributes of 3D printed prostheses include visual appeal, ease of donning, and customization of parameters to improve upper-limb symmetry offers a promising option to familiarize new amputee patients with the use of a prosthesis. Rapid manufacturing and remote fitting allows 3D printed devices to serve as postoperative transitional devices and may function as definitive devices with minimal loss of functionality if standard clinic-based prostheses are not available. Methods The patient was a 59-year-old male with a traumatic transradial amputation of the dominant arm. A 3D printed transradial prosthesis was remotely fitted and manufactured using photogrammetry. Assessments were performed initially with the standard-hook prosthesis and then with the 3D printed device after a 5-week familiarization period. Functional outcomes were evaluated using the Box and Block Test and Bimanual Coordination Tray Test. Patient satisfaction was evaluated using two self-reported questionnaires (the QUEST 2.0 and the modified OPUS).

Funder

Biomechanics Rehabilitation and Manufacturing Initiative

National Institute of Neurological Disorders and Stroke

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Biomedical Engineering,General Medicine,Biomaterials,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3