Accuracy of magnetic resonance imaging in defining dentate line in anal fistula

Author:

Liu Xiuxiang,Wang Zhenchang,Ren Hua,Wang Zheng,Li Jing

Abstract

Abstract Purpose To retrospectively assess the accuracy of magnetic resonance imaging (MRI) in defining dentate line in anal fistula. Materials and methods Seventy patients with anal fistulas were assessed by dynamic contrast-enhanced MRI. The distance from the dentate line to the anal verge for all patients was measured by MRI. To mitigate interference, 35 patients with anal fistulas whose internal openings were located on the dentate line were excluded from this study. Two observers independently judged the positional relationship between the internal opening and the MRI-defined dentate line, and compared with the results observed by surgeon to assess the accuracy. Results The distance between the MRI-defined dentate line and the anal verge depended on the location of the internal opening and the morphology of the anal canal mucosa. The distance based on the location the internal opening and the morphology of the anal canal mucosa was 18.2 ± 8.1 mm and 20.0 ± 5.3 mm on oblique coronal T2WI, respectively. Compared with the results observed by the surgeon, the accuracy of evaluating the positional relationship between the internal opening and the dentate line from the morphology of the anal canal mucosa on MRI exceeded 89.9%. Taking 18.2–20.0 mm as the distance between the dentate line and the anal verge on the MRI image, the accuracy of evaluating the relationship between the position of the internal opening and the dentate line was over 85.7%. Considering both the dentate line and the anal canal mucosa, the accuracy of evaluating the relationship between the internal opening and the dentate line was over 91.5%. The results of MRI-defined dentate line were in good agreement with the results of intraoperative surgeon evaluation, and the κ values were 0.70, 0.63, and 0.78, respectively. Conclusion MRI has high accuracy in defining the dentate line in anal fistulas.

Funder

Science and Technology Innovation Project of China Academy of Chinese Medical Sciences

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3