The accuracy and influencing factors of Doppler echocardiography in estimating pulmonary artery systolic pressure: comparison with right heart catheterization: a retrospective cross-sectional study

Author:

Lv Guang-jie,Li Ai-li,Tao Xin-cao,Zhai Ya-nan,Zhang Yu,Lei Jie-ping,Gao Qian,Xie Wan-mu,Zhai Zhen-guo

Abstract

Abstract Background Noninvasive assessment of pulmonary artery systolic pressure by Doppler echocardiography (sPAPECHO) has been widely adopted to screen for pulmonary hypertension (PH), but there is still a high proportion of overestimation or underestimation of sPAPECHO. We therefore aimed to explore the accuracy and influencing factors of sPAPECHO with right heart catheterization (RHC) as a reference. Methods A total of 218 highly suspected PH patients who underwent RHC and echocardiography within 7 days were included. The correlation and consistency between tricuspid regurgitation (TR)-related methods and RHC results were tested by Pearson and Bland–Altman methods. TR-related methods included peak velocity of TR (TR Vmax), TR pressure gradient (TR-PG), TR mean pressure gradient (TR-mPG), estimated mean pulmonary artery pressure (mPAPECHO), and sPAPECHO. With mPAP ≥ 25 mm Hg measured by RHC as the standard diagnostic criterion of PH, the ROC curve was used to compare the diagnostic efficacy of sPAPECHO with other TR-derived parameters. The ratio (sPAPECHO–sPAPRHC)/sPAPRHC was calculated and divided into three groups as follows: patients with an estimation error between − 10% and + 10% were defined as the accurate group; patients with an estimated difference greater than + 10% were classified as the overestimated group; and patients with an estimation error greater than − 10% were classified as the underestimated group. The influencing factors of sPAPECHO were analyzed by ordinal regression analysis. Results sPAPECHO had the highest correlation coefficient (r = 0.781, P < 0.001), best diagnostic efficiency (AUC = 0.98), and lowest bias (mean bias = 0.07 mm Hg; 95% limits of agreement, − 32.08 to + 32.22 mm Hg) compared with other TR-related methods. Ordinal regression analysis showed that TR signal quality, sPAPRHC level, and pulmonary artery wedge pressure (PAWP) affected the accuracy of sPAPECHO (P < 0.05). Relative to the good signal quality, the OR values of medium and poor signal quality were 0.26 (95% CI: 0.14, 0.48) and 0.23 (95% CI: 0.07, 0.73), respectively. Compared with high sPAPRHC level, the OR values of low and medium sPAPRHC levels were 21.56 (95% CI: 9.57, 48.55) and 5.13 (95% CI: 2.55, 10.32), respectively. The OR value of PAWP was 0.94 (95% CI: 0.89, 0.99). TR severity and right ventricular systolic function had no significant effect on the accuracy of sPAPECHO. Conclusions In this study, we found that all TR-related methods, including sPAPECHO, had comparable and good efficiency in PH screening. To make the assessment of sPAPECHO more accurate, attention should be paid to TR signal quality, sPAPRHC level, and PAWP.

Funder

Capital Health Research and Development of Special Fund

National Natural Key Clinical Specialty Construction Project

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

Reference21 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3