Comparing the symmetry of upper eyelid following unilateral ptosis correction

Author:

Aytogan HasanORCID,Ayıntap EmreORCID

Abstract

Abstract Background Margin Reflex Distance 1(MRD 1) only describes the central height of upper eyelid and relies on the examiner’s experience and disregards eyelid contour abnormalities. Therefore MRD 1 may not be sufficient for an acceptable result to evaluate the outcomes of ptosis surgery. The primary purpose of this study was to assess outcomes of unilateral ptosis correction based on parameters including degree of symmetry, MRD 1, peak height of the upper lid, temporal and nasal ocular surface area, and temporal/nasal area ratio with an objective, quantitative, and repeatable method. Methods This study was designed as a retrospective non-randomized case-control study. Medical records of the patients with unilateral ptosis between October 2015 and December 2020 were reviewed. Patients with unilateral ptosis who underwent surgical correction and levator function of 5 mm or greater were included in the study. Two groups were defined; ptotic eye was case group and contralateral eye was control group. Data analysis was performed Image J and Matlab softwares. Results Thirty-four patients were included in the study. Mean age of patients was 58.8 ± 12.7 years (range 15–75 years). Mean follow-up time was 19.5 ± 7.3 months (range 8–40 months). Four patients were diagnosed with congenital ptosis and 30 patients aponeurotic ptosis. Mean preoperative degree of symmetry for overall eyelid contour was 36.6 ± 27.5% (range 1–92%). Mean postoperative degree of symmetry for overall eyelid contour was 72.4 ± 16.5% (range 55–92%). Temporal/Nasal (T/N) area ratios for contralateral normal eye was 1.19 pre-postoperative, and it was 1.11 preoperatively, 1.15 postoperatively for operated ptotic eye. Conclusions This study primarily demonstrated a quantitative, objective, and repeatable method to investigate the degree of symmetry after eyelid surgeries. Secondly, this study suggested that T/N ratio may not be a reliable parameter to evaluate the eyelid symmetry.

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3