Analysis of a novel hydrophobic acrylic enhanced monofocal intraocular lens compared to its standard monofocal type on the optical bench

Author:

Borkenstein A. F.ORCID,Borkenstein E. M.,Schmid R.

Abstract

Abstract Introduction The aim of this laboratory study is to objectively analyze the new hydrophobic, acrylic, enhanced monofocal intraocular lens Acunex Quantum (AN6Q) and compare it with the monofocal platform Acunex AN6.  Methods Two IOL models were analyzed (Acunex Quantum AN6Q and Acunex AN6, Teleon Surgical, Spankeren, Netherlands), each having the same refractive power of + 22.0 D, on the optical bench with the OptiSpheric IOL PRO 2. The measurements followed the guidelines of the International Standard Organization with following parameters: ISO 2 cornea (+ 0,28 µ), ISO 11979/2, lens placement in situ in NaCl with 35° temperature, 546 nm and selection of different aperture sizes (3.0 mm vs 4.5 mm). The aberrations of each IOL were evaluated by the WaveMaster IOL 2, a high-resolution Shack-Hartmann sensor in reverse projection setup. An in-situ model eye was used according to ISO 11979 in NaCl (n = 1.337) with 546 nm, mask width 4.51. Zernike polynomials up to 10th order were determined by means of the measured wavefront that describe the optical properties of the IOL. Results Through frequency modulation transfer function (mean) at 50 lp/mm (AN6Q/AN6 centered) was 0.687/0.731 (3.0 mm aperture) and 0.400/0.509 (4.5 mm aperture). The SR (mean) was 0.592/0.809 (3.0 mm) and 0.332/0.372 (4.5 mm). The MTF (mean) at 50 lp/mm (AN6Q/AN6 decentered by 1 mm) was 0.413/0.478 (3.0 mm) and 0.257/0.229 (4.5 mm). The SR (mean) was 0.393/0.404 (3.0 mm) and 0.183/0.212 (4.5 mm). The MTF (mean) at 50 lp/mm (AN6Q/AN6 tilted by 5°) was 0.508/0.710 (3.0 mm) and 0.337/0.513 (4.5 mm). The SR (mean) was 0.508/0.760 (3.0 mm) and 0.235/0.2372 (4.5 mm). AN6Q showed MTF peak of 0.55 with an enlarged depth of power of about 2.5 D and two cusps in the MTF curve. The spherical aberration Z 4–0 was about -0.21 µm and the secondary spherical aberration Z 6–0 was about 0.16 µm. No other relevant aberration showed up. Conclusion The new, enhanced monofocal AN6Q provides an extended range of focus with only slight decrease in contrast quality. Both types of the hydrophobic, acrylic Acunex IOL platform have its particular advantages in clinical settings and therefore its importance, respectively.

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

Reference12 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3