Abstract
Abstract
Background
Despite much evidence supporting the monitoring of the divergence of transcutaneous partial pressure of carbon dioxide (tcPCO2) from arterial partial pressure carbon dioxide (artPCO2) as an indicator of the shock status, data are limited on the relationships of the gradient between tcPCO2 and artPCO2 (tc-artPCO2) with the systemic oxygen metabolism and hemodynamic parameters. Our study aimed to test the hypothesis that tc-artPCO2 can detect inadequate tissue perfusion during hemorrhagic shock and resuscitation.
Methods
This prospective animal study was performed using female pigs at a university-based experimental laboratory. Progressive massive hemorrhagic shock was induced in mechanically ventilated pigs by stepwise blood withdrawal. All animals were then resuscitated by transfusing the stored blood in stages. A transcutaneous monitor was attached to their ears to measure tcPCO2. A pulmonary artery catheter (PAC) and pulse index continuous cardiac output (PiCCO) were used to monitor cardiac output (CO) and several hemodynamic parameters. The relationships of tc-artPCO2 with the study parameters and systemic oxygen delivery (DO2) were analyzed.
Results
Hemorrhage and blood transfusion precisely impacted hemodynamic and laboratory data as expected. The tc-artPCO2 level markedly increased as CO decreased. There were significant correlations of tc-artPCO2 with DO2 and COs (DO2: r = − 0.83, CO by PAC: r = − 0.79; CO by PiCCO: r = − 0.74; all P < 0.0001). The critical level of oxygen delivery (DO2crit) was 11.72 mL/kg/min according to transcutaneous partial pressure of oxygen (threshold of 30 mmHg). Receiver operating characteristic curve analyses revealed that the value of tc-artPCO2 for discrimination of DO2crit was highest with an area under the curve (AUC) of 0.94, followed by shock index (AUC = 0.78; P < 0.04 vs tc-artPCO2), and lactate (AUC = 0.65; P < 0.001 vs tc-artPCO2).
Conclusions
Our observations suggest the less-invasive tc-artPCO2 monitoring can sensitively detect inadequate systemic oxygen supply during hemorrhagic shock. Further evaluations are required in different forms of shock in other large animal models and in humans to assess its usefulness, safety, and ability to predict outcomes in critical illnesses.
Publisher
Springer Science and Business Media LLC
Subject
General Biochemistry, Genetics and Molecular Biology,General Medicine
Reference47 articles.
1. Gutierrez G, Reines HD, Wulf-Gutierrez ME. Clinical review: hemorrhagic shock. Crit Care. 2004;8(5):373–81.
2. Cannon JW. Hemorrhagic shock. N Engl J Med. 2018;378(4):370–9.
3. Chatterjee K. The Swan-Ganz catheters: past, present, and future a viewpoint. Circulation. 2009;119(1):147–52.
4. Litton E, Morgan M. The PiCCO monitor: a review. Anaesth Intensive Care. 2012;40(3):393–409.
5. Rajaram SS, Desai NK, Kalra A, Gajera M, Cavanaugh SK, Brampton W, Young D, Harvey S, Rowan K. Pulmonary artery catheters for adult patients in intensive care. Cochrane Database Syst Rev. 2013;2:CD003408.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献