‘BLUES’ procedure for assessing the blue level of the sclera in Osteogenesis Imperfecta

Author:

Di Martino Valerio,Mallone Fabiana,Lambiase AlessandroORCID,Celli Mauro,Mannocci Alice,Celli Luca,Mangiantini Pietro,Fino Pasquale,Moramarco Antonietta

Abstract

Abstract Purpose Blue sclera is a characteristic and common clinical sign of Osteogenesis Imperfecta (OI). However, there is currently no widely accepted, objective method for assessing and grading blue sclera in individuals with OI. To address this medical need, this study is aimed to design and validate a new method called ‘BLUES’ (BLUe Eye Sclera) to objectively identify and quantify the blue color in the sclera of patients affected by OI. Methods Sixty-two patients affected by OI and 35 healthy controls were enrolled in the present prospective study, for a total of 194 eyes analyzed. In the 'BLUES' procedure, eye images from patients with OI and control subjects were analyzed to assess and grade the blue level of the sclera using Adobe Photoshop Software. The validation process then involved comparing the results obtained with the ‘BLUES’ procedure to the judgement of experienced ophthalmologists (JEO). A receiver-operating characteristic (ROC) curve analysis was used to examine the overall discriminatory power. The sensitivity and specificity levels and the Cohen's Kappa (K) indexes of ‘BLUES’ and ‘JEO’ were estimated versus the standard OI diagnosis. The K indexes of ‘BLUES’ versus ‘JEO’ were also evaluated. Results The optimal cut-off point of the scleral blue peak was calculated at 17%. Our findings demonstrated a sensitivity of 89% (CI95%: 0.835–0.945) and specificity of 87% (CI95%: 0.791–0.949) for the ‘BLUES’ procedure with an agreement versus the diagnosis of OI of 0.747. In comparison, the sensitivity and specificity of ‘JEO’ ranged from 89 to 94% and 77% to 100%, respectively, with an agreement ranging from 0.663 to 0.871 with the diagnosis of OI. The agreement between ‘BLUES ‘and ‘JEO’ evaluations ranged from 0.613 to 0.734. Conclusions Our findings demonstrated an 89% sensitivity and an impressive 87% specificity of our method to analyze the blue sclera in OI. The results indicated high agreement with disease diagnosis and were consistent with evaluations by experienced ophthalmologists. The ‘BLUES’ procedure appears to be a simple, reliable and objective method for effectively identify and quantify the blue color of the sclera in OI.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3