One-year outcomes of polymer-free amphilimus-eluting stents versus durable polymer zotarolimus-eluting stents in patients with diabetes mellitus: a meta-analysis

Author:

Wang Hong,Xie Xiaoya,Zu Quannan,Lu Ming,Chen Rongfa,Yang Zhiren,Gao Yongqiang

Abstract

Abstract Background Diabetes mellitus (DM) and cardiovascular diseases often co-exist. Today, percutaneous coronary intervention (PCI) is the preferred revascularization procedure for majority of patients with coronary artery disease. Polymer-free amphilimus-eluting stents (AES) represent a novel elution technology in the current era of drug-eluting stents. In this analysis, we aimed to systematically compare the cardiovascular outcomes which are associated with polymer-free amphilimus-eluting stents (AES) versus the durable polymer zotarolimus-eluting stents (ZES) for the treatment of patients with DM. Methods Http://www.ClinicalTrials.gov, EMBASE, Web of Science, MEDLINE, Cochrane database and Google Scholar were searched for publications comparing polymer-free AES versus durable polymer ZES in patients with DM. Selective cardiovascular outcomes were assessed. Statistical analysis was carried out by the latest version of the RevMan software. Risk ratio (RR) with 95% confidence interval (CI) was used to represent the data analysis. Results Four studies with a total number of 1795 participants with DM whereby 912 patients were assigned to be revascularized by the polymer-free AES and 883 patients were assigned to be revascularized by the durable polymer ZES were included in this analysis. In patients with DM, at one year, polymer-free AES were associated with significantly lower risk of major adverse cardiac events (MACEs) (RR: 0.69, 95% CI: 0.54–0.88; P = 0.002) and target lesion failure (TLF) (RR: 0.66, 95% CI: 0.48–0.91; P = 0.01) compared to durable polymer ZES. However, there was no significant change in all-cause mortality (RR: 0.79, 95% CI: 0.51–1.22; P = 0.28), cardiac death and the other cardiovascular outcomes. Similar risk of total stent thrombosis (RR: 1.13, 95% CI: 0.60–2.13; P = 0.70), including definite stent thrombosis (RR: 1.12, 95% CI: 0.38–3.31; P = 0.84), probable stent thrombosis (RR: 0.87, 95% CI: 0.37–2.09; P = 0.76), possible stent thrombosis (RR: 1.19, 95% CI: 0.50–2.87; P = 0.69) and late stent thrombosis (RR: 1.00, 95% CI: 0.17–5.72; P = 1.00) as between polymer-free AES and durable polymer ZES in patients with DM. Conclusions At 1 year follow-up, polymer-free AES were associated with significantly lower MACEs and TLF compared to durable polymer ZES in these patients with DM, without any increase in mortality, stent thrombosis and other cardiovascular outcomes. However, this analysis is only based on a follow-up time period of one year, therefore, future research should focus on the long term follow-up time period.

Funder

Guangxi Key Research and Development Program

Guangxi Medical and Health Appropriate Technology Development and Promotion Application Project

Guangxi Nanning Qingxiu District Science and Technology Development Project

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,Endocrinology, Diabetes and Metabolism

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3