A retrospective study of dynamic navigation system-assisted implant placement

Author:

Ma Lijuan,Ye Mingjun,Wu Mingle,Chen Xiaolei,Shen Shan

Abstract

Abstract Background To evaluate the accuracy of implant placement assisted by a dynamic navigation system, as well as its influencing factors and learning curve. Methods At Macao We Care Dental Center, 55 cases of implant placement using dynamic navigation were retrospectively evaluated. To evaluate their accuracy, the apex, tip, and angle deviations of preoperatively planned and postoperatively placed implants were measured. The effects of the upper and lower jaws, different sites or lateral locations of dental implants, and the length and diameter of the implants on accuracy were analyzed, as well as the variation in accuracy with the increase in the number of surgical procedures performed by dentists. Results The implant had an apex deviation of 1.60 ± 0.94 mm, a tip deviation of 1.83 ± 1.03 mm, and an angle deviation of 3.80 ± 2.09 mm. Statistical differences were observed in the tip deviation of implants at different positions based on three factors: jaw position, lateral location, and tooth position (P < 0.05). The tip deviation of the anterior teeth area was significantly greater than those of the premolar and molar areas. There were no statistically significant differences in apex deviation, tip deviation, or angle deviation between the implants of different diameters and lengths (P > 0.05). There were significant differences in the angle deviation between the final 27 implants and the first 28 implants. Learning curve analysis revealed that angle deviation was negatively correlated with the number of surgical procedures, whereas the regression of apex deviation and tip deviation did not differ statistically. Conclusions The accuracy of dynamic navigation-assisted dental implants meets the clinical needs and is higher than that of traditional implants. Different jaw positions, lateral locations, and implant diameters and lengths had no effect on the accuracy of the dental implants guided by the dynamic navigation system. The anterior teeth area had a larger tip deviation than the posterior teeth area did. As the number of dynamic implantation procedures performed by the same implant doctor increased, the angle deviation gradually decreased.

Funder

Self-funded Science and Technology Plan Project of Foshan in 2020

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3