Hemodynamic effects of supplemental oxygen versus air in simulated blood loss in healthy volunteers: a randomized, controlled, double-blind, crossover trial

Author:

Lie Sole LindvågORCID,Hisdal Jonny,Rehn Marius,Høiseth Lars Øivind

Abstract

Abstract Background Trauma patients frequently receive supplemental oxygen, but its hemodynamic effects in blood loss are poorly understood. We studied the effects of oxygen on the hemodynamic response and tolerance to simulated blood loss in healthy volunteers. Methods Fifteen healthy volunteers were exposed to simulated blood loss by lower body negative pressure (LBNP) on two separate visits at least 24 h apart. They were randomized to inhale 100% oxygen or medical air on visit 1, while inhaling the other on visit 2. To simulate progressive blood loss LBNP was increased every 3 min in levels of 10 mmHg from 0 to 80 mmHg or until hemodynamic decompensation. Oxygen and air were delivered on a reservoired face mask at 15 L/min. The effect of oxygen compared to air on the changes in cardiac output, stroke volume and middle cerebral artery blood velocity (MCAV) was examined with mixed regression to account for repeated measurements within subjects. The effect of oxygen compared to air on the tolerance to blood loss was measured as the time to hemodynamic decompensation in a shared frailty model. Cardiac output was the primary outcome variable. Results Oxygen had no statistically significant effect on the changes in cardiac output (0.031 L/min/LBNP level, 95% confidence interval (CI): − 0.015 to 0.077, P = 0.188), stroke volume (0.39 mL/LBNP level, 95% CI: − 0.39 to 1.2, P = 0.383), or MCAV (0.25 cm/s/LBNP level, 95% CI: − 0.11 to 0.61, P = 0.176). Four subjects exhibited hemodynamic decompensation when inhaling oxygen compared to 10 when inhaling air (proportional hazard ratio 0.24, 95% CI: 0.065 to 0.85, P = 0.027). Conclusions We found no effect of oxygen compared to air on the changes in cardiac output, stroke volume or MCAV during simulated blood loss in healthy volunteers. However, oxygen had a favorable effect on the tolerance to simulated blood loss with fewer hemodynamic decompensations. Our findings suggest that supplemental oxygen does not adversely affect the hemodynamic response to simulated blood loss. Trial registration This trial was registered in ClinicalTrials.gov (NCT05150418) December 9, 2021

Funder

Stiftelsen Norsk Luftambulanse

University of Oslo

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3