Muscle ultrasound shear wave elastography for detection of early onset lower limb ischemia in patients with veno-arterial extracorporeal membrane oxygenation

Author:

Maslarska MariyaORCID,Piepenburg Sven,Westermann Dirk,Supady Alexander,Hehrlein Christoph

Abstract

Abstract Background and objectives Limb ischemia or compartment syndrome, requiring surgery, are some of the frequent cannula-related complications in patients supported with veno-arterial extracorporeal membrane oxygenation (VA-ECMO). The purpose of this exploratory study is to depict and evaluate the dynamic changes in the lower limb muscles with ultrasound shear wave elastography as marker for early lower limb ischemia. Methods Eleven patients with VA-ECMO after cardiac arrest were included in this study. Seven patients received distal perfusion cannula (DPC) after implantation of the VA-ECMO, whereas 4 had no DPC after VA-ECMO. Compartment syndrome was clinically excluded in all patients. Both lower limbs, e.g., with and without arterial cannula, were monitored with near-infrared spectroscopy (NIRS) for the oxygen saturation of the local tissue. We performed ultrasound shear wave elastrography (SWE) to assess dynamic changes of the medial gastrocnemius muscle at maximum passive muscle stretch (exercise) of both legs. Color-coded duplexsonography was conducted to examine the blood flow velocity of the popliteal artery of the lower limb. Results We found no difference between DPC and no DPC (p = 0.115) during use of VA-ECMO. However, we detected marked lower limb muscle perfusion deficits of cannulated (58.9 ± 13.5 kPa) vs. cannula-free limb (95.7 ± 27.9 kPa: p < 0.001), applying SWE. No relationship was detected between NIRS measurements and SWE values (kPa) of both lower limbs. The mean peak systolic velocity of the popliteal artery at the cannulated side (30.0 ± 11.7 cm/s) was reduced compared to the non-cannulated side (39.3 ± 18.6 cm/s; p = 0.054). Conclusions Regardless of DPC after implantation of VA-ECMO, the gastrocnemius muscles seem to lose function due to cannula-related microcirculatory deficits. Muscle function analysis via SWE combined with NIRS might offer a sensitive indicator for early onset leg ischemia during VA-ECMO-related arterial cannulation.

Funder

Universitätsklinikum Freiburg

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3